22
3.  After powering up the components, connect the MATE to the HUB.
a)  Plug the MATE into the 1st MATE Port on the HUB.
b)  The MATE will power up and should recognize any component connected to the HUB. 
c)  The MATE can then program the FXs.
d)  The  fth MATE screen (“Port Assignment”) should display all the FXs and any OutBack Charge 
Controllers in the  system.
   MATE Screens
   PATH                              
    G’day            (C) 2004  Version  Searching  Port Assignment
               OutBack   Code a.aa  for Devices  1> FX  2> FX  3> CC 4> CC
       Power        5>        6>        7>       8>
                                     Systems  Serial #xxxxxxxx  HUB Found  9>        10>      2M>
      Screen EE b.bb
4.  To verify the MATE recognizes each HUB connected FX and OutBack Charge Controller, disconnect 
and then either (a) reconnect the MATE to view its boot-up and repoll sequence or (b) follow this path 
to manually repoll:
   PATH
   M
AIN--------------------- SETUP----------------  SETUP/MATE/PAGE1  SETUP/MATE/PAGE2  SETUP/MATE/COMM
   12.15:30p  choose device:  mate code rev: 402  choose category:  choose produce:     
  choose category:
   SUM STATUS SETUP ADV  FX                        MATE  CLOCK CNT GLOW PG2  PG1 SUMRY COMM MAIN  BACK REPOLL PC DEBUG
The FXs are now ready to be programmed according to the stacking options described in the next section.