53
BATTERY CHARGING INSTRUCTIONS
Keeping your battery bank energized is very important. Although a battery bank can last for many
years if properly cared for, it can also be ruined in a short period of time if neglected.
Battery Charging Setpoints
To preserve your batteries, always follow your battery manufacturer’s recommendations using the
following information:
• Absorb Voltage
• Float Voltage
• Equalize Voltage
• Recommended Depth of Discharge (DOD) of the batteries
These Absorb, Float, and Equalize voltage set points should be programmed into the FX through the
MATE (see MATE User Manual).
Maintenance
Please contact OutBack Power Systems Technical Services for any FX repairs due to malfunctions or
damage. For routine, user-approved maintenance:
• Disconnect all circuit breakers and related electrical connections before doing any cleaning or adjustments.
• Solar modules may produce hazardous voltages when exposed to light; cover them with opaque material
before servicing any connected equipment.
• If a remote or automatic generator start system is used, disable the automatic starting circuit and/or disconnect
the generator from its starting battery while servicing.
ADV/FX/AUX---------------P00
diversion 30 sec
o delay
DOWN INC DEC PORT
The diversion o relay determines how long the
AUX will be energized after the battery voltage
which caused the diversion falls below the
diversion on setpoint. This relay can range from
0-240 seconds in one-second increments as
adjusted with and .
ADV/FX/AUX----------------P00
diversion 14.6 vdc
on setpoint
DOWN INC DEC PORT
After deciding on Divert DC or Divert AC, use
the diversion on setpoint screen to choose the
voltage which will activate this AUX OUTPUT
FUNCTION. This value can range from 12.0VDC-
16.0VDC and can be adjusted in 0.1VDC incre-
ments using and . Press
to view the diversion o delay screen.
INC DEC DOWN
INC DEC