Important Safety Instructions

 

Table 1

Terms and Definitions

 

 

 

Term

Definition

 

 

 

 

DVM

Digital Voltmeter

 

 

 

ETL

Electrical Testing Laboratories; short for the company ETL Semko; refers to a certification issued by

 

ETL to OutBack products indicating that they meet certain UL standards

 

 

FCC

Federal Communications Commission

 

 

GND

Ground; a permanent conductive connection to earth for safety reasons; also known as Chassis

 

Ground, Protective Earth, PE, Grounding Electrode Conductor, and GEC

 

 

Grid-interactive,

Utility grid power is available for use and the inverter is a model capable of returning (selling)

grid-intertie, grid-tie

electricity back to the utility grid

 

 

HBX

High Battery Transfer; a function of the remote system display

 

 

IEEE

Institute of Electrical and Electronics Engineers; refers to a series of standards and practices for the

 

testing of electrical products

 

 

LBCO

Low Battery Cut-Out; set point at which the inverter shuts down due to low voltage

 

 

 

LED

Light-Emitting Diode

 

 

 

 

NEC

National Electric Code

 

 

 

NEU

AC Neutral; also known as Common

 

 

Off-grid

Utility grid power is not available for use

 

 

 

PV

Photovoltaic

 

 

 

RELAY AUX

Auxiliary connection that uses switch (relay) contacts to control external devices.

 

 

RTS

Remote Temperature Sensor; accessory that measures battery temperature for charging

 

 

Split-phase

A type of utility electrical system with 2 “hot” lines that are 120 Vac with respect to neutral and 240

 

Vac between the “hot” lines; common in North America

 

 

System display

Remote interface device (such as the MATE3), used for monitoring, programming and

 

communicating with the inverter; also called “remote system display”

 

 

UL

Underwriters Laboratories; refers to a set of safety standards governing electrical products

 

 

Utility grid

The electrical service and infrastructure supported by the electrical or utility company; also called

 

“mains”, “utility service”, or “grid”

 

 

 

General Safety

WARNING: Limitations on Use

This equipment is NOT intended for use with life support equipment or other medical equipment or devices.

CAUTION: Equipment Damage

Only use components or accessories recommended or sold by OutBack Power

Technologies or its authorized agents.

2

900-0020-01-00 Rev A

Page 4
Image 4
Outback Power Systems GS8048 manual General Safety, Important Safety Instructions