Setup Parameter

Values

Description

 

 

 

 

 

 

 

 

 

 

INTERFACE TYPE

parallel, serial, automatic,

Selects the interface type. In case of ‘automatic’ the

 

 

 

auto+blink

interface type is selected by the printer depending on data

 

 

 

 

coming from host. When the auto+blink item is selected,

 

 

 

 

the P1 and P2 leds blink to indicate which interface is

 

 

 

 

selected: P1 blinks when the serial interface is selected,

 

 

 

 

whereas P2 blinks when the parallel interface is selected.

 

 

 

 

 

 

 

 

 

INPUT BUFFER

1 Kb, 8 Kb, 16 Kb, 32 Kb

Selects the buffer size.

 

 

 

 

 

 

 

 

 

IGNORE PE

enabled, disabled

Selects whether the printer signals the paper empty

 

 

 

 

disabled

enabled

 

 

 

 

 

condition (

) or not (

).

 

 

 

AUTOFEED

disabled, enabled

 

enabled

 

 

 

The parallel interface uses (

) or does not use

 

 

SIGNAL

 

disabled

) the AUTOFEED signal.

 

 

 

 

(

 

 

 

SLCT-IN SIGNAL

disabled, enabled

 

enabled

 

 

 

The parallel interface uses (

) or does not use

 

 

 

 

disabled

) the SELECT-IN signal.

 

 

 

 

 

(

 

 

 

BUFFER

DTR+SRTS, SRTS,

Selection of the buffer protocol.

 

 

 

CONTROL

XON/XOFF,

 

 

 

 

 

 

 

XON/XOFF+DTR+SRTS

 

 

 

 

 

 

 

 

 

 

 

 

 

ROBUST XON

enabled, disabled

 

enabled

disabled

 

 

Perform the Robust XON (

) or not (

).

 

 

WORD LENGTH

7 bit, 8 bit

Sets the number of the data bits.

 

 

 

 

 

 

 

 

 

 

BAUD RATE

600 - 38400 bps

Sets the data transfer rate.

 

 

 

 

 

 

 

 

 

 

PARITY BIT

Even, odd, none

Selects the parity control for the data.

 

 

 

SECURITY MODE

enabled, disabled

Enables or disables the security actions that assure

 

 

 

 

protection against paper jams. If disabled, the paper

 

 

 

 

37