Basic Operation (continued)
FRONT PANEL DISPLAY LED DESCRIPTIONS
Power On Indicator | Line Fault Indicator |
This LED is illuminated when | This LED will illuminate to warn the user that a |
the utility condition is normal | wiring problem such as a bad/missing ground or |
and the UPS outlets are pro- | reversed wiring exists within the AC receptacle. |
viding clean, protected power. | If illuminated, disconnect all equipment and contact |
| an electrician to insure outlet is properly wired. |
Unsafe Voltage Indicator
This LED will illuminate to inform the user that an unsafe line voltage is present and that the UPS has switched to battery power. This could be either an
Battery Level Indicator
This is a visual indication of the battery charge. If battery capac- ity is under 25%, no indicator LED will illuminate and UPS starts beeping (if the audible alarm is enabled).
| POWER ON |
BATTERY LEVEL | LINE FAULT |
| UNSAFE VOLTAGE |
| BATTERY MODE |
| AVR MODE |
LOAD LEVEL
1 2 3 4
Load Level Indicator
This is a visual indication of the UPS load.
The 1st arrow will illuminate when the load is above 25%, the 2nd above 50% and the 3rd above 75%. The 4th arrow will flash when the load is between 85% and 100%.
Battery Mode Indicator
This illuminates during utility failure or an unsafe voltage condition, indicating that the battery is supplying power to the connected equipment.
AVR Indicator
This indicates that the UPS is operating in automatic voltage regulation mode. When the led is illu- minated continuously, it indicates an input
REAR PANEL DESCRIPTION
Non-Critical-Load Outlets
Four battery powered, surge protected and AVR outlets for connected equipment insures temporary uninterrupted oper- ation of connected equipment during a power failure.
Critical Load Outlets
Two battery powered, surge protected and AVR outlets for
AC Power
Cord Input
Receptacle
IR Control Section
Learning Control Switches – Push to program or test the IR function IR Detector Window – Receives the IR signal to be learned Indicator LED’s – Indicates learning status
Output Delay Switches – Set the desired time delay between a power failure and when the IR signals are sent to the connected equipment
IR Output Jacks – Standard 1/8” (3.5mm) mono jack for connection to an IR flasher (IR flashers not included)
NON CRITICAL
LOAD OUTLET
BANK
12
CRITICAL
LOAD
OUTLET
BANK
3
MAIN
AC INPUT
OUTPUT DELAY | IR DETECTOR |
IR1
30 SEC. 5 MIN.
IR2
IR OUTPUT | PROGRAM / TEST |
INOUT
RS232 CONTROL
Circuit Breakers for Overload Protection
Resettable circuit breakers provide optimal overload protection.
RS232 Serial Communication Port |
|
| RJ11/RJ45 Jacks |
| |||
The serial port allows connection and communication between | Ports protect stan- | ||
the UPS and a HTPC (home theater personal computer) or home | dard telephone line, | ||
automation system. If used temporarily during setup (with the | modem, or network | ||
included software), it allows the installer to program a number of | cable. | ||
variables including the Critical Load Battery Threshold. See the |
| ||
software documentation for more information. |
|
USA & Canada (800) |
| 3 |