Panamax M1500-UPS Battery Features continued, Diagnostics, Battery Replacement Procedure

Models: M1500-UPS

1 20
Download 20 pages 13.1 Kb
Page 13
Image 13
Battery Features (continued)

Battery Features (continued)

Battery Replacement Procedure

Pure Sine Wave

Intelligent

Critical Load Control

MAX® Home

Cinema UPS

1.Remove the right side front panel using pull-out handles.

2.Remove the two retaining screws of the cable protection cover then remove the cover.

3. Disconnect the black and red cable.

6. Slide a new battery pack into the unit.

Assemble the screws, cover, cable and front

panel in the reverse sequence of above steps.

Battery pullout tab handle

4. Remove the four retaining screws.

5. Pull the battery pack out from the unit.

7. Recharge the unit for 4-8 hours to ensure

the UPS performs expected runtime.

Diagnostics

Power

Wiring

AVR LED

Using

Circuit

Audible

Condition

On LED

Fault LED

 

Battery LED

Breaker

Alarm

 

 

 

 

 

 

 

 

On

Off

Off

Off

Set

Off

Normal

 

 

 

 

 

 

 

On

Off

Slow Flash

Off

Set

Off

AVR- Max. boost 13% of input voltage for output regulation while input voltage is

 

 

 

 

 

 

from 8% to 15% under nominal.

 

 

 

 

 

 

 

On

Off

Rapid Flash

Off

Set

Off

AVR- Max. boost 26% of input voltage for output regulation while input voltage is

 

 

 

 

 

 

from 15% to 26% under nominal.

 

 

 

 

 

 

 

On

Off

On

Off

Set

Off

AVR- Max. buck 15% of input voltage for output regulation while input voltage is

 

 

 

 

 

 

from 8% to 26% over nominal.

 

 

 

 

 

 

 

Off

Off

Off

On

Set

Two Beeps

Utility Failure- The UPS is providing battery power to the connected equipment.

 

 

 

 

 

 

 

Off

Off

Off

On

Set

Rapid Beeps

Utility Failure- The UPS is providing battery power. Rapid beeps indicate the battery

 

 

 

 

 

 

will run out of charge within a few minutes.

 

 

 

 

 

 

 

On/Off

Off

On/Off/Flash

On/Off

Set

Long Beep

Overload- Turn the UPS off and unplug at least one piece of equipment from the UPS.

 

 

 

 

 

 

Wait 5 seconds, reset the circuit breaker and restart the UPS.

 

 

 

 

 

 

 

Off

Off

Off

On

Up

Long Beep

Overload- Turn the UPS off and unplug at least one piece of equipment from the UPS.

 

 

 

 

 

 

Wait 5 seconds, reset the circuit breaker and restart the UPS.

 

 

 

 

 

 

 

On

Off

On/Off/Flash

Off

Set

None

Weak Battery- Recharge the battery for at least 8 hours. If Check Battery is illuminat-

 

 

 

 

 

 

ed, contact Panamax for battery replacement information.

 

 

 

 

 

 

 

Off

Off

Off

Off

Set

Off

Surge Protection Malfunction- Power surge has damaged the unit. Please contact

 

 

 

 

 

 

Panamax.

 

 

 

 

 

 

 

On/Off

On

On/Off/Flash

On/Off

Set/Up

None

Electrical Wiring Fault- Indicates wiring problems such as a bad ground, missed

 

 

 

 

 

 

ground or reversed wiring within the AC outlet. User is advised to disconnect all

 

 

 

 

 

 

electrical equipment from the outlet and have the outlet checked by an electrician.

 

 

 

 

 

 

 