– 34 –
Setup menus
USER menu
The underline on the setting item denotes the initial setting.
Item Setting
No.
Superimposed
display
Description
No.
Superimposed
display
201 9P SEL 0000
0001 OFF
ON
This selects whether the 9P connector functions when the
REMOTE/LOCAL switch has been set to REMOTE.
0:
1:
202 ID SEL 0000
0001 OTHER
DVCPRO
This selects the ID information which is returned to the
controller.
0:
1: 20 25H
DVCPRO’s, own ID is returned (F0 33H).
<INTERFACE>
Do not function
Function
204 RS232C SEL 0000
0001 OFF
ON
These settings are for selecting whether the RS-232C
connector is to function when the REMOTE/LOCAL switch is
set to REMOTE.
0:
1: Connector does not function.
Connector functions.
205 BAUD RATE 0000
0001
0002
0003
0004
0005
300
600
1200
2400
4800
9600
These settings are for selecting the RS-232C communication
speed (baud rate).
206 DATA
LENGTH 0000
0001 7
8
These settings are for selecting the RS-232C data length.
(Unit: bit)
207 STOP BIT 0000
0001 1
2
These settings are for selecting the RS-232C stop bit length.
(Unit: bit)
208 PARITY 0000
0001
0002
NON
ODD
EVEN
These settings are for selecting the none, odd or even for the
RS-232C parity bit.
0:
1:
2:
Parity bit is not used.
An odd number of bits is used for the parity system.
An even number of bits is used for the parity system.
209 RETURN
ACK 0000
0001 OFF
ON
These settings are for selecting whether the ACK code is to
be returned when a command is received from RS-232C.
0:
1: ACK code is not returned.
ACK code is returned.