100
Setting menu screens (VTR MAIN MENU)
<Note>
When USER is set for the UB MODE item, it is not possible to set
EXT for the VITC UB MODE item.
Similarly, it is not possible to set EXT for the UB MODE item when
USER has been set for the VITC UB MODE item.
TC/UB screen
The time code and users bit settings are performed on
this screen.
Item Variable
range Remarks
TC MODE DF
NDF
VF
display Item Variable
range Remarks
VF
display
USER
ENG
For setting the time code
to the DF or NDF mode.
DF
:The time code is set
to the drop frame
mode.
NDF
:The time code is set
to the non-drop
frame mode.
UB MODE USER
DATE
TIME
EXT
TCG
USER
ENG
For setting what is to be
written as the users bit in
the LTC area.
USER
:User setting (fixed).
DATE
:Real time value for
year/month/day/hou
rs.
TIME
:Real time value for
hours/minutes/seco
nds.
EXT
:The UBG value is
slave-locked when
a TC signal is
supplied from an
external source.
(The user setting is
used when no
external input is
supplied.)
TCG
:Time code
generator value
<Note>
Set the time on the
TIME/DATE menu screen
when using the UB MODE
item with real-time
operation.
TCG SET HOLD ON
OFF
USER
ENG
For selecting the operation
of TCG when the TCG
SET 5power OFF 5
power ON 5REC
operations are performed.
ON
:The TCG setting is
stored when the
power is turned off,
and is not
regenerated.
OFF
:The TCG setting is
not stored when the
power is turned off,
but is regenerated.
P. OFF LCD
DISPLAY
ON
OFF
USER
ENG
For setting whether the
LCD display is to appear
when the power is OFF.
ON
:The LCD display
appears even when
the power is OFF.
OFF
:The LCD display
does not appear
when the power is
OFF.
The power-saving
mode is established.
TC OUT TCG
TCG/TCR
USER
ENG
For selecting the time
code which is to be output
to the time code output
connector.
TCG
:
The time code generated
by the time code
generator is output at all
times.
TCG/TCR
:
The time code generated
by the time code
generator is output in the
E-E mode; the time code
reader value is output in
the V-V mode.
The underlining in the variable range column indicates the setting in the preset mode.
FIRST REC TC REGEN
PRESET
USER
ENG
For setting the TC REGEN
mode when recording is
started.
REGEN
:
The time code set on the
tape is regenerated.
PRESET
:
The time code set on the
tape is not regenerated.
However, it is forcibly
regenerated when the
unit is transferred from
the rec-pause mode to
the recording mode.