Panasonic AJ-SD755 operating instructions Error messages, OVTR operation and corrective action

Models: AJ-SD755

1 78
Download 78 pages 11.87 Kb
Page 67
Image 67
OVTR operation and corrective action

Error messages

Error messages

Display

ODescription

 

 

 

OVTR operation and corrective action

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally

 

high, the error number flashes on the display.

S REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally

 

high, the error number flashes on the display.

T REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-69

If excess torque being applied to the take-up

 

reel motor is detected, the error number flashes

T REEL

on the display.

 

 

 

TORQUE ERR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-70

If excess torque being applied to the supply reel

 

motor is detected or an abnormal current flowing

S REEL

to the current detection resistor is detected, this

TORQUE ERR

error number flashes on the display.

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-71

If abnormal tension at the supply side is

 

detected in the capstan mode, the error number

CAP TENSION

flashes on the display.

 

 

ERROR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-72

If abnormal tension at the supply side is

 

detected in the reel mode, the error number

REEL

flashes on the display.

 

 

TENSION

VTR: STOP

 

 

 

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the

 

reverse direction, this error number flashes on

REEL DIR

the display.

 

 

 

UNMATCH

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-74

If excess torque being applied to the cylinder

 

motor is detected, this error number flashes on

DRUM

the display.

 

 

 

TORQUE

VTR: STOP

 

 

 

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-78

If a problem has been encountered in

 

communication

between

the

servo

M-IF COMM

microcomputer and mechanism relay board, this

ERROR

error number flashes on the display.

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

 

 

 

Consult your dealer if the error message is still displayed even after restarting the unit.

67

Page 67
Image 67
Panasonic AJ-SD755 Error messages, OVTR operation and corrective action, motor is detected or an abnormal current flowing