Chapter 4 Adjustments and settings for recording
Concerning the user bit setting during external lock
When the unit’s time code is externally locked, only the time data is locked to the time data of the time code supplied from the external source. This means that the user bits can be set separately for each component.
When the <TC/UB> screen is opened from the VTR menu page and EXT is selected as the UB MODE item setting by performing menu operations, the user bits can also be locked to the user bits of the time code supplied from the external
4-5-5 Setting the UMID information
This unit supports metadata UMIDs. As the UMID data, the user must first set the name of his or her country (with 3 or fewer characters), the name of the company or organization (with 4 or fewer characters), and the user name (with 4 or fewer characters). Input the name of the country based on the Country Codes (21) stipulated under the ISO 3166 standard.
Given here as an example is the procedure for inputting the
source.
user name.
4
To release the external lock
First stop supplying the external time code, and set the TCG switch to
When switching the power from the battery to an external power supply while the time code is externally locked
In order to ensure the continuity of the time code generator’s power, connect the external power supply to the DC IN connector, and then remove the battery pack. If the battery pack is removed first, no guarantees can be made for the continuity of the external locking of the time code.
Gen-locking of the camera unit while the time code is externally locked
While the time code is externally locked, the camera unit is
<Notes>
O When locking the external time code to a multiple number of units with this unit serving as the master, the same mode as the unit’s camera mode must be set. Bear in mind that no guarantees can be made for the continuity of the images and time code if both the interlace and progressive formats are used together in the system.
O When the signal from the unit’s MON OUT connector is to be used as the reference video signal, first set the OUTPUT SEL switch on the side panel to the CAM position.
O The unit cannot be
21 Examples:
CHN for China, USA for United States, CAN for Canada, and JPN for Japan
<UMID SET/INFO >
| COUNTRY | :*** |
| ORGANIZATION | :**** |
# | USER | :**** |
**DEVICE NODE**
1 Open the <UMID SET/INFO> screen from the VTR menu page by performing a menu operation.
2 Turn the JOG dial button to move the arrow (cursor) to the “USER” item.
3 When the JOG dial button is pressed, the arrow (cursor) moves to the USER input area, and the input mode is established.
4 Press the JOG dial button again and turn it until the character to be set is displayed.
When the button is turned, the character displayed is switched in the following sequence:
Space: ∑ 7
letters:
numbers:
symbols: ’, >, <, /, –
<Note>
Only spaces and letters can be selected for the COUNTRY item. This does not apply to other items.
5 Press the JOG dial button to enter the character.
6 Turn the JOG dial button to move the arrow (cursor) to the next position (right), and repeat steps 4 and 5 to set the characters.
7 When the characters have been input, turn the JOG dial button to move the arrow (cursor) to the “:” position.
8 When the JOG dial button is pressed, the arrow (cursor) returns to the “USER” item.
9 Press the MENU button to exit the menu operations.