Chapter 7 Menu description tables

7-2 SYSTEM SETTING

7-2-1 SYSTEM MODE

 

Item/

 

 

Variable

 

 

Remarks

 

Data storage

range

 

 

 

 

 

 

 

 

 

 

 

 

 

REC SIGNAL

 

 

CAM

For selecting the video input signals.

 

 

 

 

 

VIDEO

CAM:

The signals from the camera are

 

 

 

 

 

1394

 

 

recorded.

 

 

 

 

 

 

VIDEO: The signals from the GENLOCK IN

 

 

 

 

 

 

 

 

connector are recorded.

 

 

 

 

 

 

1394:

The signals from the DVCPRO

 

 

 

 

 

 

 

 

connector are recorded.

 

 

 

 

 

 

<Note>

 

 

 

 

 

 

 

 

CAM is always set when the power is next

 

C U

F

E

 

turned on after it being turned off.

 

 

 

 

 

REC MODE

 

 

16:9/50M

For selecting the mode in which to record the

 

 

 

 

 

4:3/50M

signals on the VTR.

 

SDC905

 

 

 

 

 

 

 

16:9/25M

16:9/50M: <16:9> signals are recorded at 50

 

 

 

 

 

4:3/25M

 

 

Mbps.

 

 

 

 

 

 

4:3/50M: <4:3> signals are recorded at 50

 

 

 

 

 

 

 

 

Mbps.

 

 

 

 

 

 

16:9/25M: <16:9> signals are recorded at 25

 

 

 

 

 

 

 

 

Mbps.

 

 

 

 

 

 

4:3/25M: <4:3> signals are recorded at 25

 

C U

F

E

 

 

 

Mbps.

 

 

 

 

 

ASPECT

 

 

16:9

For selecting the mode in which to record the

 

 

 

 

 

4:3

signals on the VTR.

 

SDC615

 

 

 

 

 

 

 

 

16:9:

 

<16:9> signals are recorded.

 

C U

F

E

 

4:3:

 

<4:3> signals are recorded.

 

 

 

 

 

SET UP 50

 

 

O%

For selecting the setup. (For 50M recording).

 

 

 

 

 

7.5%A

0%:

The setup is set to 0% for both the

 

SDC905

 

 

 

 

 

 

 

 

 

camera output signals and the signals

 

 

 

 

 

 

 

on the tape.

 

 

 

 

 

 

7.5%A: The setup is set to 7.5% for the

 

 

 

 

 

 

 

camera output signals and 0% for the

 

C U

F

E

 

 

signals on the tape.

 

 

 

 

 

SET UP

 

 

O%

For selecting the setup. (For 25M recording).

 

 

 

 

 

7.5%

0%:

The setup is set to 0% for both the

 

SDC615

 

 

 

 

 

 

 

7.5%A

 

camera output signals and the signals

SET UP 25

 

 

 

 

on the tape.

 

 

 

 

 

 

7.5%: The setup is set to 7.5% for both the

 

SDC905

 

 

 

 

 

 

 

 

 

 

camera output signals and the signals

 

 

 

 

 

 

 

on the tape.

 

 

 

 

 

 

7.5%A: The setup is set to 7.5% for the

 

 

 

 

 

 

 

camera output signals and 0% for the

 

C U

F

E

 

 

signals on the tape.

 

 

 

 

 

PB MODE

 

 

MANUAL

For selecting the playback mode.

 

 

 

 

 

AUTO

MANUAL: The playback mode accords with the

 

SDC905

 

 

 

 

 

 

 

 

 

 

25M or 50M setting of the REC

 

 

 

 

 

 

 

 

MODE item.

 

 

 

 

 

 

 

 

Operation proceeds with 16:9 or 4:3

 

 

 

 

 

 

 

 

read from the tape.

 

 

 

 

 

 

AUTO: In this mode, the recording mode is

 

 

 

 

 

 

 

 

automatically detected and playback

 

C U

F

E

 

 

 

is performed in the same mode.

Item/

Variable

 

Remarks

Data storage

range

 

 

 

 

 

 

REC TALLY

RED

For selecting the method used to inform the

 

GREEN

user that the unit is recording when a system

 

CHAR

using an extender or other device is

 

 

configured and BOTH is selected as the 26-

 

 

PIN CONTROL menu item setting while the

 

 

system is used in the remote control mode.

 

 

RED:

The red tally lamp lights.

 

 

GREEN: The green tally lamp lights.

 

 

CHAR: The letters “REC” appear on the

C U F E

 

 

viewfinder.

 

 

 

 

The underlining in the variable range column indicates the setting in the preset mode.

80