Chapter 6 Maintenance and inspections

6-3 Warning system

6-3-1 Warning description tables

When an error or a problem is detected immediately after the power is turned on or while an operation is underway, the WARNING lamp and lamps inside the viewfinder serve to alert the user.

<Note>

Items are displayed in the following sequence of priority: WARNING lamp > tally lamp > warnings inside the viewfinder. The display accords with this sequence when more than one error has occurred at the same time. However, WIRELESS RF may not be displayed depending on the menu setting selected.

1. SLACK

 

 

 

 

3. TAPE END

 

 

 

 

 

 

 

 

 

 

 

Indications on LCD screen

“SLACK” appears and an error code flashes.

 

 

Indications on LCD screen

The bar display that shows the remaining tape

 

 

 

6

 

 

 

 

 

 

amount starts flashing.

 

WARNING lamp

Flashes four times a second.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING lamp

Lights (during stop and standby OFF).

 

Tally lamp

Flashes four times a second.

 

 

 

 

 

 

 

Tally lamp

Flashes four times a second (during stop and

 

 

Viewfinder

“SLACK” appears and an error code lights up.

 

 

 

standby OFF).

 

 

 

 

 

 

 

 

 

 

Alarm

Sounds continuously.

 

 

 

 

 

 

 

 

 

 

Viewfinder

= END” flashes (during stop and standby OFF).

 

 

 

 

 

 

 

 

 

Warning description

Motor, solenoid or other mechanism-related

 

 

 

 

 

 

Alarm

Sounds continuously (during stop and standby

 

 

 

trouble, etc.

 

 

 

 

 

 

 

 

 

 

OFF).

 

 

 

 

 

 

 

 

 

 

VTR unit operation

Operation is stopped. Power is

turned

off if

 

 

 

 

 

 

Warning description

The tape has come to its end.

 

 

 

solenoid trouble has been detected.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VTR unit operation

Operation is stopped during recording, playback

 

 

Corrective action

Check “6-3-2 Error codes,” and

consult

your

 

 

 

and fast forwarding.

 

 

 

nearest service center.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Corrective action

Rewind the tape or replace the cassette tape.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. BATTERY END

Indications on LCD screen

The bar display that shows the remaining battery

 

charge starts flashing.

 

 

WARNING lamp

Lights.

 

 

Tally lamp

Flashes once a second.

 

 

Viewfinder

BATT LED lights.

 

 

Alarm

Sounds continuously.

 

 

Warning description

The battery charge is now depleted.

 

 

VTR unit operation

All operations are stopped, and the tape is

 

unloaded. Only cassette tape eject is accepted.

 

 

Corrective action

Replace the battery.

 

 

4. REC WARNING

Indications on LCD screen

The code 11 display lights.

 

 

WARNING lamp

Flashes four times a second (for at least 3

 

seconds during recording).

 

 

Tally lamp

Flashes four times a second (for at least 3

 

seconds during recording).

 

 

Viewfinder

REC WARNING display lights (for at least 3

 

seconds during recording).

 

 

Alarm

Sounds four times a second (for at least 3

 

seconds during recording).

 

 

Warning description

Problem with the recording control signal.

 

 

VTR unit operation

Recording continues but the signals may not be

 

recorded correctly while the warning remains

 

displayed.

 

 

Corrective action

Rewind the tape or replace the cassette tape.

 

 