@0Flesh Noise Suppress Level Setting [Flesh Noise

Suppress: OFF/LOW/HIGH]

Flesh noise is suppressed in two steps when the DTL Level is at HIGH or LOW.

@1Electronic Shutter Setting [Shutter Speed:

OFF/1/100 to 1/10 000/S/Scan/Auto ND] OFF: Electronic shutter is turned off.

1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10 000:

Electronic shutter operates at one of these speeds as selected.

S/Scan (Synchro Scan): Electronic shutter oper- ates at the speed set with the electronic shutter synchro-scan setting @2.

Auto ND: Electronic shutter is controlled to auto- matically adjust the luminance. (ELC)

Note

In case of using the RCU (RCB), none of the shutter speeds1/250, 1/2 000, 1/4 000, and

1/10 000 can be selected.

In case of using the hybrid control panel, only OFF, 1/100, or Auto ND (ELC) can be selected.

If the lens iris switch is at M (Manual) when oper- ating the camera alone or when the iris switch on the RCU (RCB) is at AUTO, Auto ND may not function. Set the lens iris switch to A (Auto).

Flickering may increase at Auto ND under fluo- rescent lights.

Auto ND is automatically selected if Auto ND (ELC) setting r is set to ON.

@2Electronic Shutter Synchro Scan Setting [Synchro Scan: 60.58Hz - 15.75kHz]

This setting is possible only when Electronic Shutter setting @1is at S/Scan.

Horizontal bar noise can be reduced by synchro- scan adjustment in shooting workstation scenes, for example.