Useful Information
Registration
Follow the procedure below when you want to:
•Add an additional terminal to your
•
1.Confirm that the mode selector of the master adaptor is set to
MASTER.
2.Confirm that the mode selector of the terminal adaptor that you want to register is set to TERMINAL.
3.Plug the master adaptor and a power strip into the same wall outlet.
•Registration may not be successful if the master and power strip are connected to different wall outlets during registration.
•Make sure the power strip is turned on. Do not use a power strip with a noise filter or surge protector feature.
4.Plug the terminal adaptor into the power strip.
MASTER
MASTER TERMINAL
MASTER TERMINAL | TERMINAL |
5.Reset the terminal by pressing the FACTORY DEFAULT RESET button on the terminal for about 3 seconds (see page 20).
•Check the position of the adaptor’s mode selector (see page 13) and make sure that you reset the terminal adaptor (not the master).
6.Press the SETUP button on both adaptors for about 1 second. The order in which they are pressed does not matter.
•The PLC indicator of each adaptor will begin to flash in green.
•Make sure you press the SETUP button on each adaptor within 3 seconds of each other.