Main Menu (continued)

Restrictions on various FUNCTION settings

Under the following conditions, various settings are disabled.

Setting

Disabling condition

SD ASPECT

Does not operate while GPI items are being set. Does not operate during PIXEL TO PIXEL

 

operation.

 

Does not operate during HD display.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

WFM

Does not operate during PIXEL TO PIXEL or FOCUS-IN-RED mode.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

MARKER

Does not operate while GPI items are being set.

 

Does not operate when the VF line is selected for the input.

 

Does not operate during PIXEL TO PIXEL or FOCUS-IN-RED mode.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

PIXEL TO PIXEL

Does not operate while WFM is ON or GPI items are being set.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

FOCUS-IN-RED

Does not operate while WFM is ON or GPI items are being set.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

MONO

Does not operate while GPI items are being set.

 

If operated during the conditions described above, “INVALID FUNCTION” is displayed.

Operation status displayed when a FUNCTION button is used

When one of the buttons from [FUNCTION1] to [FUNCTION3] is pushed, one of the following displays is shown depending on the operation assigned to the button.

MARKER

MARKER OFF, 4:3 MARKER, 13:9 MARKER, 14:9 MARKER, VISTA MARKER, CNSCO MARKER, 95% MARKER, 93% MARKER, 90% MARKER, 88% MARKER, 80% MARKER

PIXEL TO PIXEL / PIXEL POSITION

CENTER, LEFT TOP, LEFT MID, LEFT BOTTOM, MID TOP, MID BOTTOM, RIGHT TOP, RIGHT MID, RIGHT BOTTOM

FOCUS-IN-RED

FOCUS-IN-RED OFF, FOCUS-IN-RED ON

ZEBRA

ZEBRA OFF, ZEBRA ON

REAR TALLY

REAR TALLY OFF, REAR TALLY ON

24