1. General

This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1.Standard screwdriver

2.Phillips head screwdriver

3.Knife or wire stripper

4.Tape measure

5.Carpenter’s level

1-2. Accessories Supplied with Unit Table 1

6.Sabre saw or key hole saw

7.Hacksaw

8.Core bits

9.Hammer

10.Drill

11.Tube cutter

12.Tube flaring tool

13.Torque wrench

14.Adjustable wrench

15.Reamer (for deburring)

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Parts

Figure

Q’ty

Remote

 

 

Tapping screw

Truss-head

 

 

 

 

 

1

Phillips

10

Clamp

 

1

controller

 

 

 

 

 

 

5/32 5/8" (4 16 mm)

 

 

 

 

Remote control

 

1

Rawl plug

 

8

Drain hose

 

1

holder

 

 

adapter

 

 

 

 

 

 

 

 

AAA alkaline

 

 

 

 

 

 

Packed in the indoor unit.

 

2

 

 

 

 

 

 

battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-3. Optional Copper Tubing Kit

2. Foamed polyethylene insulation for the specified

Copper tubing for connecting the outdoor unit to the

copper tubes as required to precise length of tubing.

Wall thickness of the insulation should be not less

indoor unit is available in kits which contain the narrow

than 5/16" (8 mm).

and wide tubing, fittings and insulation. Consult your

 

nearest sales outlet or air conditioning workshop.

3. Use insulated copper wire for field wiring. Wire size

1-4. Type of Copper Tube and Insulation Material

varies with the total length of wiring. Refer to 3-6.

Wiring Instructions for details.

If you wish to purchase these materials separately from

 

a local source, you will need:

 

1.Deoxidized annealed copper tube for refrigerant tub- ing as detailed in Table 2.

Cut each tube to the appropriate lengths 1' to 1'4"

CAUTION

Check local electrical codes

(30 cm to 40 cm) to dampen vibration between units.

 

 

and regulations before

Table 2

 

 

 

 

 

obtaining wire. Also, check

 

 

 

 

 

any specified instructions or

 

 

 

 

 

 

 

 

 

 

 

 

limitations.

Model

Narrow Tube

Wide Tube

 

Outer Dia.

Thickness

Outer Dia.

Thickness

 

 

 

 

 

 

 

 

 

 

 

 

CS-MKE7NKU

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

 

 

 

 

 

 

 

 

 

CS-MKE9NKU

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

 

 

 

 

 

 

 

 

 

CS-MKE12NKU

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

 

 

 

 

 

 

 

 

 

CS-MKE18NKU

1/4" (6.35 mm)

0.0314" (0.8 mm)

1/2" (12.70 mm)

0.0314" (0.8 mm)

 

 

 

 

 

 

 

 

 

CS-MKE24NKU

1/4" (6.35 mm)

0.0314" (0.8 mm)

5/8" (15.88 mm)

0.0393" (1.0 mm)

 

 

 

 

 

 

 

 

 