Manuals
/
Panasonic
/
Household Appliance
/
Air Conditioner
Panasonic
CS-MKE9NKU, CS-MKE7NKU, CS-MKE18NKU, CS-MKE12NKU Appendix C Installation Instructions
Models:
CS-MKE24NKU
CS-MKE12NKU
CS-MKE18NKU
CS-MKE7NKU
CS-MKE9NKU
1
100
122
122
Download
122 pages
9.57 Kb
97
98
99
100
101
102
103
104
<
>
Troubleshooting
Specs
Install
Refrigerant Flow Diagram
Dimension
Wired Remote Controller
If the self-diagnostics function fails to operate
Setting procedure
How to Identify a Serial Communication Error
TIMER lamp
Page 100
Image 100
APPENDIX C INSTALLATION INSTRUCTIONS
CS-MKE7NKU
CS-MKE9NKU
CS-MKE12NKU
CS-MKE18NKU
CS-MKE24NKU
(852-6-4190-583-00-0)
A-3
Page 99
Page 101
Page 100
Image 100
Page 99
Page 101
Contents
INDOOR UNIT CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU
CS-MKE24NKU
Wall Mounted Type Indoor Unit
DC INVERTER MULTI-SYSTEM AIR CONDITIONER
SAFETY PRECAUTIONS
If refrigerant gas leaks during the work, ventilate the room
Table of Contents
2. SPECIFICATIONS
4. REFRIGERANT FLOW DIAGRAM
8. TROUBLESHOOTING BEFORE CALLING FOR SERVICE
APPLICABLE MULTI-OUTDOOR UNITS
1. OPERATING RANGE
Temperature
Indoor Air Intake Temp
Outdoor Air Intake Temp
SPECIFICATIONS
Unit Specifications
Indoor Unit
CS-MKE7NKU
Indoor Unit
CS-MKE9NKU
Indoor Unit
CS-MKE9NKU
Indoor Unit
CS-MKE12NKU
Indoor Unit
CS-MKE12NKU
Indoor Unit
CS-MKE18NKU
Indoor Unit
CS-MKE18NKU
Indoor Unit
CS-MKE24NKU
Indoor Unit
CS-MKE24NKU
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit CS-MKE9NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKE12NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKE18NKU
Control PCB
Fan Motor
Flap Motor
Indoor Unit CS-MKE24NKU
Control PCB
Fan Motor
Flap Motor
2-3. Other Component Specifications
Temperature F C
Temperature F C
Resistance k ohm
3. DIMENSIONAL DATA
CS-MKE9NKU CS-MKE12NKU
Indoor Unit CS-MKE18NKU
CS-MKE24NKU
4. REFRIGERANT FLOW DIAGRAM
4-1. Refrigerant Flow Diagram
5-1. Air Throw Distance Charts
5. PERFORMANCE DATA
Cooling
Cooling
Cooling
Cooling
6-1. Electric Wiring Diagrams
6. ELECTRICAL DATA
ASSY
LAMP
7. FUNCTIONS
7-1. Operation Functions
Emergency operation
Auto Initial Operation Mode Selection
HIGH POWER
Timer backup
NIGHT SETBACK
Lamp colors
7-2. Protective Functions
Overload prevention during heating
Freeze prevention
Cold-air prevention during heating
8. TROUBLESHOOTING BEFORE CALLING FOR SERVICE
8-1. Precautions before Performing Inspection or Repair
8-2. Method of Self-Diagnostics
PROCEDURE
1 Self-diagnostics Lamps
INDOOR UNIT 1 OPERATION lamp 2 TIMER lamp 3 QUIET lamp
OPERATION button REMOTE CONTROL receiver
DIAGNOSIS CONTENTS
2 If the self-diagnostics function fails to operate
No indicators illuminate and the indoor fan does not rotate
Check the power voltage Blown
Check the indoor unit Is the fuse blown?
8-3. Checking the Indoor and Outdoor Units
T-RUN Test run compressor and fan motor turn ON
3 How to Identify a Serial Communication Error
3-2 Condition E12
8-4. Trouble Diagnosis of Fan Motor
8-4-1. Indoor Fan Motor
1 Noise malfunction
8-5. Noise Malfunction and Electromagnetic Interference
2 Electromagnetic interference
Page
APPENDIX A Operating Instructions
CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU
Operating Instructions Split System Air Conditioner
CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU
CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU
Model No Indoor Units
FEATURES
CONTENTS
SAFETY PRECAUTIONS
PRODUCT INFORMATION
SAFETY INSTRUCTIONS
INSTALLATION LOCATION
ELECTRICAL REQUIREMENTS
Refrigerant gas leakage may cause fire
NAMES OF PARTS
Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose
Remote Controller
Refrigerant Tubes OUTDOOR UNIT Air Outlet
UNIT DISPLAY AND OPERATION BUTTON
REMOTE CONTROLLER DISPLAY
REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER CONTINUED
OPERATION WITH THE REMOTE CONTROLLER
1. Automatic Operation
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
2. Manual Operation
3. Adjusting the Fan Speed
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
4. Night Setback Mode
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
5. QUIET Mode
6. HIGH POWER Mode
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
Remote Controller
SPECIAL REMARKS
Heating
Clicking Sound
SETTING THE TIMER
1. How to set the present time
SETTING THE TIMER CONTINUED
REPEAT timer
USING THE 1-HOUR OFF TIMER
TIPS FOR ENERGY SAVING
Setting procedure
Cancellation procedure
ADJUSTING THE AIRFLOW DIRECTION
OPERATION WITHOUT THE REMOTE CONTROLLER
CARE AND CLEANING
CARE AND CLEANING CONTINUED
WIRED REMOTE CONTROLLER
CARE AND CLEANING CONTINUED
When using a footstool or the like, be careful not to let it tip over
Removing and remounting the air intake grille
TROUBLESHOOTING BEFORE CALLING FOR SERVICE
OPERATING RANGE
Trouble
Possible Cause
SPECIFICATIONS
Page
APPENDIX B Operating Instructions
CS-MKE18NKU CS-MKE24NKU
CS-MKE18NKU
CS-MKE24NKU
Model No
Indoor Units
FEATURES
CONTENTS
SAFETY PRECAUTIONS
PRODUCT INFORMATION
SAFETY INSTRUCTIONS
INSTALLATION LOCATION
ELECTRICAL REQUIREMENTS
Refrigerant gas leakage may cause fire
Air Intakes INDOOR UNIT Air Outlet Remote Controller Drain Hose
Remote Controller
NAMES OF PARTS
Refrigerant Tubes OUTDOOR UNIT Air Outlet
UNIT DISPLAY AND OPERATION BUTTON
REMOTE CONTROLLER DISPLAY
24-hour clock with ON/OFF program Timer
Temperature display
REMOTE CONTROLLER
The temperature
REMOTE CONTROLLER CONTINUED
HIGH POWER button
MODE selector button
AUTO
REMOTE CONTROLLER CONTINUED
USING THE REMOTE CONTROLLER
Use two fresh leak-proof type-AAA alkaline batteries
USING THE REMOTE CONTROLLER CONTINUED
Remote Controller
Rear Side Remote Control Holder
To take out the remote controller, pull it forward
OPERATION WITH THE REMOTE CONTROLLER
1. Automatic Operation
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
2. Manual Operation
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
3. Adjusting the Fan Speed
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
4. Night Setback Mode
6. HIGH POWER Mode
OPERATION WITH THE REMOTE CONTROLLER CONTINUED
5. QUIET Mode
Remote Controller
SPECIAL REMARKS
Heating
Clicking Sound
SETTING THE TIMER
1. How to set the present time
SETTING THE TIMER CONTINUED
REPEAT timer
USING THE 1-HOUR OFF TIMER
Setting procedure
Cancellation procedure
2. Operation together with the DAILY ON/OFF REPEAT Timer
ADJUSTING THE AIRFLOW DIRECTION
OPERATION WITHOUT THE REMOTE CONTROLLER
CARE AND CLEANING
CARE AND CLEANING CONTINUED
How to remove the filter 1. Grasp both ends of the air
Filter
Groove Pin Air intake grille Air intake grille
WIRED REMOTE CONTROLLER
CARE AND CLEANING CONTINUED
TROUBLESHOOTING BEFORE CALLING FOR SERVICE
OPERATING RANGE
Trouble
Possible Cause
SPECIFICATIONS
Indoor Unit
CS-MKE18NKU
CS-MKE24NKU
Page
APPENDIX C INSTALLATION INSTRUCTIONS
CS-MKE7NKU CS-MKE9NKU CS-MKE12NKU CS-MKE18NKU CS-MKE24NKU
INSTALLATION INSTRUCTIONS Split System Air Conditioner
Contents
NOTE External diameter of service port R410A 5/16
For Indoor Unit
SPECIAL PRECAUTIONS
When Transporting
When Installing…
In Case of Improper Installation
Others
When Servicing
&KHFNFDUHIXOO\IRUOHDNVEHIRUHVWDUWLQJWKHWHVWUXQ
1. General
1-1. Tools Required for Installation not supplied
1-2. Accessories Supplied with Unit Table
obtaining wire. Also, check
2. Installation Site Selection
1-5. Additional Materials Required for Installation
2-1. Indoor Unit
AVOID
2-2. Embedding the Tubing and Wiring
3. How to Install the Indoor Unit
trical wiring or conduits are
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
a If Wooden Wall
b If Block, Brick, Concrete or Similar Type Wall
Fig. 13a
3-4. Removing and Installing the Grille 3-4-1. Indoor unit types
How to remove the grille
How to replace the grille
3-4-2. Indoor unit types CS-MKE18NKU, CS-MKE24NKU
Fig. 19b-1
3-6. Wiring Instructions General precautions on wiring
3-5. Shape the Indoor Side Tubing
Fig. 26a
3-7. Wiring Instructions for Inter-unit Connections
Fig. 26b
WARNING Loose wiring may cause the terminal to overheat or result
How to connect wiring to the terminal a For Indoor Unit
b For Outdoor Unit For solid core wiring or F-cable
For stranded wiring
3-8. Mounting
Right-side tubing
Fig. 37a
Fig. 37b
Switching drain hose and drain cap
Left-side tubing
Drain hose
Drain cap
Do not supply power to the
tubing and wiring to the out
To unmount indoor unit
3-9. Drain Hose
Fig. 59a Fig. 59b
4. How to Test Run the Air Conditioner
Fig. 59c
5. Remote Controller Installation Position
6. Address Switch
6-1. Address Setting of the Remote Controller
7. Connecting a Home Automation Device
8. Installation Check Sheet
Page
DC1111-0