SAFETY PRECAUTIONS

Before doing repair work, please read the "SAFETY PRECAUTIONS" carefully and fully understand them.

The precautionary items here are divided into "Warning" and "Caution" items.

Items in particular which may cause death or serious injury to the service personnel if the work is not performed correctly,

are included in the "Warning" table.

However, even precautionary items identified as " Caution" also have the potential for serious consequences if not performed correctly.

Important safety precautions are described for all items in both categories. Be sure to carefully follow all of them.

Symbol Indication

: This symbol indicates items to which we need to pay attention. In this triangle, a definite precautionary item is described.

: This symbol indicates the item to be prohibited.

In or close to this circle, a prohibited item is described.

: This symbol indicates the items requiring special attention or instruction. In or close to this circle, a prohibited item is described.

After doing repair work, perform a test run to confirm that there are no abnormalities. At the same time, explain the precautions in use to the user.

Warning

Before performing an overhaul, disconnect the power plug or power cable from the unit.

Performing the work with the power supplied to the unit, may cause an electric shock.

When repair work or circuit inspection that requires power supply for the air conditioner, is to be performed,

 

do not touch the charging section.

 

Doing so may cause an electric shock.

Prohibit

For the step-up capacitor attached to the electric section, perform the repair work after sufficiently discharging it. Insufficient capacitor discharge may cause an electric shock.

Do not perform repair work on the electric sections with wet hands.

Doing so may cause an electric shock.

Prohibit

Do not start or stop the air conditioner by means of connecting or disconnecting the power plug.

Doing so may cause an electric shock or fire.

Prohibit

When conducting repair work only use components included in the parts list for the corresponding unit and perform the work with the appropriate tools.

Incorrect or poor repair work may cause an electric shock or fire.

Never modify the unit.

Doing so may cause an electric shock or fire.

Prohibit

Perform all electric work according to local applicable regulations related to electrical equipment or interior wiring regulation and make sure to use the exclusive circuit.

Insufficient capacity to the electric circuit or defective arrangement results may cause an electric shock or fire.

Make sure to replace any power cable or lead wire showing any signs of scratch or deterioration.

Failure to do so may cause an electric shock, overheating or fire.

Make sure that there is no dust on or slack in the power plug and insert fully into the socket.

Dust or incomplete connections may cause an electric shock or fire.

Do not damage or process the power cord, as it may cause an electric shock or fire.

Prohibit

For the wiring between the indoor unit and outdoor unit, securely fix the specified cable onto the terminal plate. Poorly fixed wiring may cause a heat or fire.

After connecting the wiring between the indoor unit and outdoor unit, attach the terminal cover securely. Incomplete attachment of the terminal cover may cause overheating or fire.

2

Page 2
Image 2
Panasonic CS-MKE18NKU, CS-MKE9NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU service manual Safety Precautions

CS-MKE24NKU, CS-MKE12NKU, CS-MKE18NKU, CS-MKE7NKU, CS-MKE9NKU specifications

The Panasonic CS-MKE series comprises a range of advanced air conditioning units designed to provide efficient cooling and heating solutions for both residential and commercial spaces. The models in this series include the CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, each tailored to meet various needs while ensuring energy efficiency and user comfort.

One of the standout features of the CS-MKE series is its inverter technology. This innovative approach allows the air conditioner to adjust its compressor speed in accordance with the set temperature, leading to reduced energy consumption and lower utility bills. The inverter system operates smoothly, maintaining a consistent temperature without the bothersome on-off cycling typical of traditional units.

Moreover, the models in the CS-MKE range are equipped with the Plasma Quad Plus air purification technology. This feature effectively eliminates harmful particles and odors from the air, ensuring that the indoor environment is not only comfortable but also healthy. The air conditioning units can filter out dust, pollen, and various allergens, making them ideal for allergy sufferers or those with respiratory issues.

In terms of cooling and heating capacity, the CS-MKE series provides a versatile range. From the compact yet efficient CS-MKE7NKU, suitable for smaller rooms, to the robust CS-MKE24NKU designed for larger spaces, users can find an option that best suits their needs. Each model comes with adjustable airflow settings, allowing occupants to direct cool or warm air to where it's needed most, enhancing comfort levels.

The aesthetic design of the CS-MKE units is another appealing aspect. With their sleek and modern exterior, these air conditioners seamlessly blend into a variety of interior styles. Their ultra-quiet operation further enhances the user experience, making them suitable for bedrooms, offices, or any environment where noise reduction is a priority.

User-friendliness is a key characteristic of the CS-MKE series, boasting remote control features and programmable timers that allow users to set cooling or heating schedules, ensuring comfort upon arrival home while maximizing efficiency throughout the day.

Overall, the Panasonic CS-MKE series air conditioners, including models CS-MKE18NKU, CS-MKE7NKU, CS-MKE12NKU, CS-MKE24NKU, and CS-MKE9NKU, offer a blend of advanced technology, energy efficiency, and design sophistication, making them a commendable choice for any space.