After turning on the power of the air conditioner, use the remote controller and follow the steps below to conduct the test run.
(1)Set the remote controller in Test Run mode. (Fig. 59a)
a)Press and hold the QUIET button and the 1HR. TIMER button.
E7KHQSUHVVDQGKROGWKH$&/ 5HVHWEXWWRQZLWKD pointed object such as the tip of a pen. After 5 sec- RQGVUHOHDVHWKH$&/ EXWWRQILUVW
c)Then release the QUIET and 1HR. TIMER buttons.
d) appears and
(2)Start Cooling mode test run by pressing the ON/OFF operation button of the remote controller. (Fig. 59a)
7KLVVWDUWVWKHIDQSURGXFLQJXQFRROHGIRUFHGDLUZLWK the 3 indicator lamps (OPERATION lamp, TIMER lamp and QUIET lamp) on the main unit blinking. (Fig. 59c)
$IWHUPLQXWHVWKHV\VWHPVKLIWVLQWRFRROLQJRSHUD tion, and cool air will start to be felt. Cooling mode test run is unaffected by the room temperature.
(3)Press the ON/OFF operation button of the remote con- troller again to stop the test run. (Fig. 59a)
)LQDOO\SUHVVWKH$&/ 5HVHWEXWWRQRIWKHUHPRWHFRQ troller to release it from Test Run mode to return to nor- mal mode. (Fig. 59a)
´ µDQG´R3µZLOOGLVDSSHDUIURPWKHUHPRWHFRQ troller clock display area.
NOTE
Troubleshooting:
In the event that the green OPERATION lamp is blinking upon powering up the system, an error condition exists. In this case, refer to the
IMPORTANT
After the test run is completed, be sure to press the $&/ 5HVHWEXWWRQWRUHWXUQWRQRUPDOPRGH7KH air conditioner will not operate correctly if this is not done.
| ON/OFF | |
QUIET | operation | |
button | ||
button | ||
|
1HR.
TIMER button
ACL (Reset) button
Fig. 59b
OPERATION lamp
TIMER lamp
QUIET lamp