12.13Patrol Operation

To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation

Patrol operation starts condition

o When the unit operation is started with “OFF/ON” button

o When the unit stops, “Patrol” operation is selected, Patrol individual operation will start. o During cooling only operation, “Patrol” operation is selected.

Patrol operation stops condition (when any of the following condition is fulfilled): o When “OFF/ON” button is selected.

o During any operation with Patrol, “PATROL/e-ion” button is pressed. o When OFF Timer activates.

To disable the Patrol Operation during unit starts (default) with “OFF/ON” button

o Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to enter internal setting mode.

o Press “Timer Decrement" button to select “Pt dFLt”.

o Press “Timer Set” button to toggle Patrol operation default OFF/ON.

ƒLong "beep": Turn OFF Patrol operation default.

ƒShort "beep": Turn ON Patrol operation default.

Press continously for 15s

SET

SET

Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit Patrol demo code

(Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit ECO demo code

(Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit check code (Buzzer:Short Beep)

38

Page 38
Image 38
Panasonic CS-C18KKS, CU-C18KKS, CU-C24KKS, CS-C24KKS dimensions Patrol Operation, Transmit check code BuzzerShort Beep