Panasonic CU-C18KKS, CU-C24KKS, CS-C18KKS dimensions •Airflow direction Horizontal, Vertical Control

Models: CS-C24KKS CS-C18KKS CU-C24KKS CU-C18KKS

1 67
Download 67 pages 17.08 Kb
Page 40
Image 40

Airflow direction (Horizontal, Vertical) Control

o During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.

o During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no signal is sent to air conditioner, and no change on LCD display.

o During Patrol individual operation if e-ion stops, Airflow direction louver closed.

LED display (Applicable to all models except KKD models) o When Patrol operation is selected, Patrol LED illuminates.

o During Patrol individual operation, only Patrol LED illuminates. When e-ion air purifying operation starts based on dirtiness level, Power LED, Patrol LED and e-ion LED illuminates.

 

 

 

 

PATROL LED

 

E-ION

TIMER

 

 

 

 

 

 

 

 

No

Description

 

BLUE

ORANGE

RED

BLUE

ORANGE

 

 

 

 

 

 

 

 

1

When patrol function is not selected

OFF

OFF

OFF

-

-

 

 

 

 

 

 

 

 

2

During gas sensor error detection control

OFF

OFF

Blinking

OFF

OFF

 

 

 

 

 

 

 

 

3

During E-ion abnormal discharge error

OFF

OFF

OFF

Blinking

OFF

 

 

 

 

 

 

 

 

4

During E-ion breakdown error

OFF

OFF

OFF

Blinking

Blinking

 

 

 

 

 

 

 

 

5

During Test Mode

 

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

6

During stop

 

OFF

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

7

2 minutes gas sensor initial stabilization time (Level 0)

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

 

 

a. Dirtiness level 0*

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

 

 

8

During operation

b. Dirtiness level 1

OFF

ON

OFF

OFF

OFF

During patrol

c. Dirtiness level 1*

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

d. Dirtiness level 2

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

Remote Control Receiving Sound

o

Normal Operation

Î Patrol Mode

: Beep

o

Patrol Mode

Î Stop

: Long Beep

o

Patrol Mode

Î Normal Operation

: Beep

o

Stop

Î Patrol

: Beep

Timer Control

o When ON timer activates when unit stops, previous operation resumes and restored last saved Patrol operation status.

o When ON timer activates during any operation, no change and carry on current operation.

o When OFF timer activates during any operation, all operation stops and the latest Patrol operation status is saved.

Power Failure Control

o During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes immediately.

o During combination operation, if power failure occurs, after power resumes combination operation resume immediately.

40

Page 40
Image 40
Panasonic CU-C18KKS, CU-C24KKS, CS-C18KKS, CS-C24KKS dimensions •Airflow direction Horizontal, Vertical Control