Panasonic CS-C18KKS, CU-C18KKS, CU-C24KKS, CS-C24KKS dimensions Condition of the

Models: CS-C24KKS CS-C18KKS CU-C24KKS CU-C18KKS

1 67
Download 67 pages 17.08 Kb
Page 54
Image 54
Condition of the

15.1.1Relationship between the condition of the air conditioner and pressure and electric current

Condition of the

 

Cooling Mode

 

 

 

 

air conditioner

Low Pressure

High Pressure

Electric current during operation

 

 

 

 

Insufficient refrigerant

Ô

Ô

Ô

(gas leakage)

 

 

 

Clogged capillary tube or

Ô

Ô

Ô

strainer

 

 

 

Short circuit in the indoor unit

Ô

Ô

Ô

 

 

 

 

Heat radiation deficiency

Ò

Ò

Ò

of the outdoor unit

 

 

 

Inefficient compression

Ò

Ô

Ô

 

 

 

 

• Carry out the measurement of pressure, electric current, and temperature fifteen minutes after an operation is started.

15.1.2Diagnosis methods of a malfunction of a compressor

Nature of fault

Insufficient compressing of a compressor

Locked compressor

Symptom

Electric current during operation becomes approximately 20% lower than the normal value.

The discharge tube of the compressor becomes abnormally hot (normally 70°C to 90°C).

The different between high pressure and low pressure becomes almost zero.

Electric current reaches a high level abnormally, and the value exceeds the limit of an ammeter. In some cases, a breaker turns off.

The compressor has a humming sound.