12.14E-ion operation
•This operation provides clean air by producing negative ions to attract dust captured at the positively charged active e-ion filters.
•e-ion operation start condition
o During unit running at any operation mode, if “e-ion” operation is selected, combination operation (operation mode + e-ion operation) starts.
o During unit is OFF, if “e-ion” operation is selected, e-ion individual operation starts.
•e-ion operation stop condition
o When “OFF/ON” button is pressed to stop the operation. o When “PATROL/e-ion” button is pressed.
o When OFF Timer activates.
•e-ion operation pause condition
o When indoor fan stop (during deice, odor cut control, thermostat off, etc.). e-ion operation resume after indoor fan restarts.
o When indoor intake temperature ≥ 40°C. e-ion operation resume after indoor intake temperature < 40°C continuously for 30 minutes.
•Indoor fan control
o During any operation mode combines with e-ion operation, fan speed follows respective operation mode. o During e-ion individual operation – only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to air conditioner, and no change on LCD display.
Auto Fan Speed for e-ion operation switches from SHi to Hi after 4 hours of operation.
•Airflow direction control
o During any operation mode combines with e-ion operation, airflow direction follows respective operation mode.
o During e-ion individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no signal is sent to air conditioner, and no change on LCD display.
•Timer control
o When ON timer activates when unit stops, previous operation resumes and restored last saved e-ion operation status.
o When ON timer activates during any operation, no change and carry on current operation.
o When OFF timer activates during any operation, all operation stops and the latest e-ion operation status is saved.
•Indicator
o When e-ion operation starts, e-ion indicator ON.
•Remote Control Receiving Sound
o | Normal Operation | Î e-ion Operation | : Beep |
o | e-ion Operation | Î Normal Operation | : Beep |
o | Stop | Î e-ion individual Operation | : Beep |
o | e-ion individual Operation | Î Stop | : Long Beep |
•Power failure
o During e-ion individual operation, if power failure occurs, after power resumes, e-ion individual operation resumes immediately.
o During combination operation, if power failure occurs, after power resumes, combination operation resume immediately.
o e-ion operation status is not memorized after OFF the unit. After OFF, when the operation is ON again, air conditioner operates without e-ion operation.