14. Servicing Mode

14.1 Auto OFF/ON Button

Auto OFF/ON

Auto OFF/ON

Button Pressed

Button Pressed

 

 

5 sec

 

 

 

 

 

 

Auto Operation

Test Run Operation

Stop

 

 

(Forced Cooling Operation)

 

Auto OFF/ON

 

Button Pressed

 

5 sec

 

Various Setting Mode

 

 

Stop

 

 

 

 

 

 

1AUTO OPERATION MODE

The Auto Operation will be activated immediately once the Auto OFF/ON button is pressed. This operation can be used to operate air conditioner with limited function if remote control is misplaced or malfunction.

2TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)

The Test Run Operation will be activated if the Auto OFF/ON button is pressed continuously for more than 5 seconds. A “beep” sound will be heard at the fifth seconds, in order to identify the starting of this operation.

3VARIOUS SETTING MODE

The Various Setting Mode will be activated if (within 20 seconds of Test Run Operation) the Auto OFF/ON button is pressed for more than 5 seconds. 2 “beep” sounds will be heard to identify the starting of this operation.

Under Various Setting Mode, user could perform the following operation: i. Press Auto OFF/ON button to toggle remote control receiving sound.

-Short “beep”: Turn ON remote control receiving sound.

-Long “beep”: Turn OFF remote control receiving sound.

After Auto OFF/ON button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON Mode is restarted.

ii. Remote Control Number Switch.

 

 

 

 

- There are 4 types of remote control transmission code could be selected and stored in EEPROM of

indoor unit. The indoor unit will only operate when received signal with same transmission code from

remote control. This could prevent signal interference when there are 2 or more indoor units installed

nearby together.

 

 

 

 

- To change remote control transmission code, short or open jumpers at the remote control printed circuit

board.

 

 

 

 

 

 

Remote Control Printed Circuit Board

J A

J - A

Jumper A (J-A)

Jumper B (J-B)

Remote Control No.

 

 

Short

Open

A (Default)

J_B

J - B

Open

Open

B

 

 

Short

Short

C

 

 

Open

Short

D

- During Various Setting Mode, press any button at remote control to transmit and store the desired

transmission code to the EEPROM.

 

 

 

- After signal is received, the Various Setting Mode is cancelled and return to normal operation.

- If there is no code is transmitted of Auto OFF/ON button is not pressed within 20 seconds, the

Various Setting Mode will be cancelled.

 

 

 