ECO Patrol Sensor abnormality check mode

Purpose is to improve sensor serviceability when sensor is malfunction.

(1)Control starting condition

When all of the conditions are formed

ƒNot in ECO Patrol Demo mode.

ƒECO Patrol mode ON.

ƒWhen ECO Patrol sensor check mode signal is received; the procedure of selection is as shown:

Press “Set” button continuously for 15 seconds by using pointer to enter internal setting mode.

Press “Timer Decrement" button to select “CHC”.

Confirm setting by pressing “Timer Set” button, a “beep” sound will be heard.

Press continously for 15s

SET

SET

Transmit Patrol default OFF/ON code (Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit Patrol demo code

(Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit ECO demo code

(Buzzer: OFF:Long Beep, ON:Short Beep)

SET

Transmit check code (Buzzer:Short Beep)

(2)Control ending condition.

When any of the conditions are formed

ƒOperation stops.

ƒ“Timer Cancel” button pressed.

ƒWhen ECO Patrol sensor check mode signal is not received for more than 30 seconds.

(3)Control content.

ƒDuring ECO Patrol mode ON, when check signal is received, if (1) or (2) is detected.

ECO Patrol LED start blinking (ECO Patrol sensor operation stops but the unit operates as normal) and ECO Patrol sensor abnormal code is memorized (the 4 times counter is ignored)

ƒThe blinking of ECO Patrol LED can be cancelled by pressing ECO Patrol button again.

ƒSensor error counter can be cleared only after power supply reset or “AC Reset” button on remote control is pressed.

However, if there is no ECO Patrol sensor abnormally happen, ECO Patrol sensor operation will continues as normal.