7-3-4. Remove the indoor air temperature sensor.

7-3-4. Remove the indoor air temperature sensor.

(1)Disconnect the connector CN08 (ROOM 2P) in the control box and remove the indoor air temperature sensor. (Fig. 10)

Indoor air temperature sensor

CN08

Fig.10

7-3-5. Remove the power box and control box.

(1)Remove a screw and remove the terminal cover. (Fig. 11)

(2)Remove the 2 screws and remove the power box cover. (Fig. 11)

(3)Disconnect the power lines (No. 1 and No. 2) / signal line (No. 3) and ground cable from the terminals in the power box. (Fig. 12)

Terminal cover

Screw

Screw

Power box cover

Fig.11

1Fig.107-3-5. Remove the power box and control box.Fig.11Fig.12 2 Manual backgroundManual background 3

Ground cable

Terminal

Power lines / Signal line

Fig.12