Panasonic CU-KE12NK1, CS-KE12NB41 service manual CS-KE18NB4UW& CZ-18BT1U, CU-KE18NKU

Models: CZ-18BT1U CS-KE12NB41 CS-KE18NB4UW CU-KE18NKU CU-KE12NK1

1 69
Download 69 pages 14.27 Kb
Page 32
Image 32
Manual background

Indoor Unit

: CS-KE18NB4UW & CZ-18BT1U

 

 

 

 

 

 

 

Outdoor Unit

: CU-KE18NKU

 

 

 

 

 

 

 

 

 

 

Power Supply : 230V Single Phase 60Hz

 

 

 

 

 

 

 

 

 

< Heating Capacity >

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY:

20,400 BTU/h

 

AIR FLOW RATE:

 

383 CFM

 

 

OUTDOOR

 

 

 

 

 

INDOOR

 

 

 

 

ENT. TEMP. oF (oC)

 

 

 

 

AMBIENT TEMP. oF (oC)

 

 

 

 

 

 

WB

 

 

 

60

65

 

70

75

 

80

 

 

 

 

 

 

 

(15.6)

(18.3)

 

(21.1)

(23.9)

 

(26.7)

 

 

0

(-17.8)

 

TH

 

11,350

11,400

 

11,440

11,480

 

11,510

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

(-16.1)

 

TH

 

11,720

11,770

 

11,820

11,850

 

11,890

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

(-13.3)

 

TH

 

12,600

12,650

 

12,700

12,750

 

12,780

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

(-10.6)

 

TH

 

13,520

13,580

 

13,630

13,670

 

13,710

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

(-7.8)

 

TH

 

14,540

14,600

 

14,650

14,700

 

14,730

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

(-5.0)

 

TH

 

15,610

15,670

 

15,730

15,770

 

15,810

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

(-2.2)

 

TH

 

16,730

16,800

 

16,850

16,890

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

(0.6)

 

TH

 

17,900

17,960

 

18,010

18,060

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

38

(3.3)

 

TH

 

19,050

19,120

 

19,170

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

(6.1)

 

TH

 

20,290

20,350

 

#

20,400

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

48

(8.9)

 

TH

 

21,550

21,610

 

20,410

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

53

(11.7)

 

TH

 

22,830

22,230

 

20,410

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

58

(14.4)

 

TH

 

23,990

22,230

 

20,410

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

(17.2)

 

TH

 

23,990

22,230

 

20,410

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

(18.3)

 

TH

 

23,990

22,230

 

20,410

18,590

 

16,770

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH : Total Heating Capacity (BTU/h)

NOTE

1.Rating conditions (#) : Indoor Unit Entering Air Temp. 70 °F (21.1 °C) DB

:Outdoor Ambient Temp. 47 °F (8.3 °C) DB / 43 °F (6.1 °C) WB

2.Above data does not take Defrost Operation, Overload Prevention Protection, and/or Cold Air Prevention Protection during heating operation into account. For this reason, the value may vary from the actual heating characteristics.

3.Above data represents the value when the operation frequency of a compressor is fixed.

32