Panasonic CS-KE12NB41 High Power, Night Setback, Lamp colors, Timer backup, COOL and DRY modes

Models: CZ-18BT1U CS-KE12NB41 CS-KE18NB4UW CU-KE18NKU CU-KE12NK1

1 69
Download 69 pages 14.27 Kb
Page 48
Image 48
 HIGH POWER

 HIGH POWER operation from remote controller HIGH POWER

This function acts to raise the power but keeps the AC system in the same operating mode.

This function is set with the HIGH POWER button on the remote controller.

(It can be set regardless of the temperature and fan speed settings.)

 NIGHT SETBACK HIGH POWER operation from remote controller

The unit operates at maximum output for 30 minutes, regardless of the desired temperature.

The fan speed is 1 step above "High."

Frequency

MAX

 COOL and DRY modes NIGHT SETBACK

 Lamp colors When NIGHT SETBACK operation is set, the temperature and fan speed settings will be adjusted automatically to allow comfortable sleep.

 HEAT mode When NIGHT SETBACK operation is set, "OPERATION lamp mark" appears on the remote controller. The main unit display lamp also becomes dimmer.

TIMER lamp COOL and DRY modes

When the night setback mode is selected, the air conditioner automatically raises the temperature setting 2°F(1°C) when 30 minutes have passed after the selection was made, and then another 2°F(1°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle cooling is needed.

0

Time

30 min. 5 min.

Start End

NOTE

Setting temperature

Press the NIGHT SETBACK button

2°F(1°C)

 

 

2°F(1°C)

 

 

30 min.

30 min.

Time

 

 

HIGH POWER lamp When HIGH POWER operation ends, the unit operates at low Hz for 5 minutes, regardless of the thermostat OFF conditions.

 Timer backup When in DRY mode, operation is in the cooling zone.

Manual background Lamp colors

OPERATION lamp

Manual background HEAT mode

When the night setback mode is selected, the air conditioner automatically lowers the temperature setting 4°F(2°C) when 30 minutes have passed after the selection was made, and then another 4°F(2°C) after another 30 minutes have passed, regardless of the indoor temperature when night setback was selected. This enables you to save energy without sacrificing comfort. This function is convenient when gentle heating is needed.

HEAT operation

Red

DRY operation

Orange

COOL operation

Green

FAN operation

Green

DEFROSTING operation

Red and Orange

 

alternately

OPERATION lamp

Green

TIMER lamp

Green

HIGH POWER lamp

Green

Manual background Timer backup

Manual background Operation stops if there are no operator controls for 25 hours or longer after unit operation switched from OFF to ON by use of ON timer operation.

Setting temperature

Press the NIGHT SETBACK button

 

4°F(2°C)

 

 

 

4°F(2°C)

30 min.

30 min.

Time

 

 

48

Page 48
Image 48
Panasonic CS-KE12NB41 High Power, Night Setback, Lamp colors, Timer backup, HIGH POWER operation from remote controller