Panasonic CU-KE18NKU, CU-KE12NK1, CS-KE18NB4UW, CS-KE12NB41, CZ-18BT1U service manual 3-2Condition E12

Models: CZ-18BT1U CS-KE12NB41 CS-KE18NB4UW CU-KE18NKU CU-KE12NK1

1 69
Download 69 pages 14.27 Kb
Page 56
Image 56
(3-2) Condition: E12

(3-2) Condition: E12

Troubleshooting Serial Communication

1.Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is turned OFF.

2.Disconnect the cable from the terminal 3 on the Outdoor

unit terminal strip.

(Fig. 6)

1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.

2.Perform the self-diagnosis five seconds after the operation start.

Condition: E01

What is the latest self-diagnosis result ?

Condition: E12

1.Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is turned OFF.

2.Disconnect the cable from the terminal 3 on the indoor

unit terminal strip.

(Fig. 7)

1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.

2.Perform the self-diagnosis five seconds after the operation start.

Condition: E01

What is the latest self-diagnosis result ?

Condition: E12

Defect in the indoor unit

P.C. board

Outdoor Unit

1

2

3

4

5

6

 

 

 

 

 

 

 

 

Power

1 2 3

Indoor Unit

Fig. 6

Defect in the outdoor unit

P.C. board

Outdoor Unit

1

2

3

4

5

6

 

 

 

 

 

 

 

 

Power

1 2 3

Indoor Unit

Fig. 7

Defect in the inter-unit

cable

56

Page 56
Image 56
Panasonic CU-KE18NKU, CU-KE12NK1, CS-KE18NB4UW, CS-KE12NB41, CZ-18BT1U service manual 3-2Condition E12