Panasonic CS-KE18NB4UW, CU-KE12NK1, CU-KE18NKU, CS-KE12NB41 Unit Specifications, Voltage Rating

Models: CZ-18BT1U CS-KE12NB41 CS-KE18NB4UW CU-KE18NKU CU-KE12NK1

1 69
Download 69 pages 14.27 Kb
Page 7
Image 7

2. SPECIFICATIONS

2-1. Unit Specifications

2-1-1.Indoor Unit

CS-KE12NB41 & CZ-18BT1U

 

 

 

 

 

 

Outdoor Unit

CU-KE12NK1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

115V Single-Phase 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

 

Heating

Performance

 

 

 

 

 

 

 

Air Circulation (Hi/Me/Lo)

ft3/min (m3/h)

235(399) / 206(350) / 194(330)

 

268(455) / 247(420) / 224(381)

 

Total Capacity

 

 

 

BTU/h

11,900

( 3,000 to 11,900 )

 

13,600

( 3,000 to 13,600 )

 

 

 

 

 

kW

3.5

( 0.9 to 3.5 )

 

4.0

( 0.9 to 4.0 )

 

Sensible Capacity

 

 

 

BTU/h

 

7,200

 

 

-

 

Latent Capacity

 

 

 

BTU/h

 

4,700

 

 

-

 

 

 

 

 

 

 

 

 

 

 

Moisture Removal (High)

 

Pints/h

 

4.26

 

 

-

 

Available Voltage Range

 

V

 

104 to 126

 

 

Running Amperes

 

 

 

A

12.6

( 2.5 to 12.6 )

 

14.6

( 2.5 to 14.6 )

Rating

Power Input

 

 

 

W

1,260

( 250 to 1,260 )

 

1,460

( 250 to 1,460 )

 

 

 

 

 

 

Power Factor

 

 

%

 

87

 

 

87

Electrical

EER

 

 

 

BTU/h/W

 

9.44

 

 

-

HSPF

 

 

 

BTU/Wh

 

-

 

 

8.5

 

COP

 

 

 

W/W

 

-

 

 

2.74

 

SEER

 

 

 

BTU/Wh

 

16

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Locked Rotor Amperes

 

A

 

20

 

 

Fuse or Circuit Breaker Capacity

 

A

 

20

 

 

Controls / Temperature Control

 

 

 

Microprocessor / I.C. Thermister

 

Control Unit

 

 

 

 

 

Wireless Remote Control Unit

 

Timer

 

 

 

 

24-Hour ON or OFF Timer, 1-Hour OFF Timer

 

Fan Speeds

 

Indoor / Outdoor

 

Auto and 3 steps / Auto (Hi, Me, Lo)

 

Airflow Direction (Indoor)

 

Horizontal

 

 

-

 

 

 

 

 

 

Vertical

 

Auto

 

 

Air Filter

 

 

 

 

 

Washable, Anti-Mold

 

Features

Compressor

 

 

 

 

 

DC Rotary (Inverter)

 

Refrigerant / Amount charged at shipment

 

Ibs (g)

 

R410A / 2.43 (1,100)

 

 

 

 

Refrigerant Control

 

 

 

 

 

Electric Expansion Valve

 

 

 

 

 

 

 

 

 

 

 

 

Operation Sound

 

Indoor : Hi/Me/Lo

 

dB-A

 

34 / 32 / 31

 

 

35 / 34 / 32

 

 

 

Outdoor : Hi

 

dB-A

 

47

 

 

49

 

Refrigerant Tubing Connections

 

 

 

Flare Type

 

 

Max. allowable tubing length at shipment

 

ft (m)

 

25 (7.5)

 

 

Refrigerant

 

Narrow tube

 

inch (mm)

 

1/4 (6.35)

 

 

Tube Diameter

 

Wide tube

 

inch (mm)

 

3/8 (9.52)

 

 

Wired Remote Controller (Option)

 

 

 

CZ-RD515U

 