( Continued from the previous page A. )

( Continued from the previous page B. )

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

Yes

 

 

Is the voltage of about DC22V to

 

 

 

 

 

24V given between the terminals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 and 3 on the indoor unit terminal strip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Serial Communication Line) ?

 

 

 

 

 

 

 

 

 

 

 

 

 

(Fig. 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

Defect or connection error

 

 

 

 

Defect in the indoor unit

 

in the inter-unit cable

 

 

 

 

 

 

P.C. board

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

1. Turn OFF the power and wait until the power lamp (LED)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the outdoor unit controller is turned OFF.

 

 

 

 

1

2

3

4

5

6

 

2. Short-circuit between the terminals 2 and 3 on the outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unit terminal strip.

(Fig. 3)

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.

2.Perform the self-diagnosis five seconds after the operation start.

What is the latest self-diagnosis result ?

Condition: E01

Condition: E12

1 2 3

Indoor Unit

Fig. 3

Defect in the outdoor unit

P.C. board.

1.Turn off the power and wait until the power lamp (LED) of the outdoor unit controller is turned OFF.

2.Remove the short-circuit between the terminals 2 and 3 on the outdoor unit terminal strip.

3.Disconnect the cable from the terminal 3 on the indoor unit

terminal strip.(Fig. 4)

Short-circuit between the terminals 2 and 3 on the indoor unit

terminal board.

(Fig. 5)

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

 

1

2

3

 

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

 

 

 

 

 

 

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 4

 

 

 

 

 

 

 

 

 

 

 

Fig. 5

 

 

 

 

 

1.Turn ON the power and operate the system using the remote controller or the operation button on the indoor unit.

2.Perform the self-diagnosis five seconds after the operation start.

Condition: E12

What is the latest self-diagnosis result ?Defect or connection error in the inter-unit cable

Condition: E01

Defect in the indoor unit

P.C. board

52

Page 52
Image 52
Panasonic CS-KS24NKU, CU-KS24NKUA service manual From the previous page a

CU-KS24NKUA, CS-KS24NKU, CU-KS24NKU specifications

The Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are a part of the company’s advanced air conditioning lineup, known for their efficient performance and user-friendly features. Designed to provide optimal cooling while ensuring energy efficiency, these models cater to both residential and commercial spaces, making them an ideal choice for various settings.

One of the standout features of the Panasonic CU-KS24NKUA and its counterparts is their inverter technology. This innovative approach allows the air conditioning units to adjust their cooling capacity based on the room's temperature, thus ensuring that they operate at peak efficiency. By minimizing energy consumption during low demand, the units not only lower electricity bills but also reduce environmental impact.

The CU-KS24NKU series is equipped with a powerful compressor that delivers high cooling performance, capable of rapidly cooling spaces even in extreme heat conditions. Additionally, with a robust SEER (Seasonal Energy Efficiency Ratio) rating, these models rank among the top in energy savings, making them suitable for energy-conscious consumers.

Continuous airflow is vital for maintaining a comfortable indoor environment, and the CS-KS24NKU includes features that enhance air circulation. Utilizing a multi-directional airflow system, these units ensure that cool air is distributed evenly throughout the room, minimizing hot spots and maximizing comfort.

Another significant characteristic of the Panasonic air conditioners is their silent operation. Designed with low noise levels in mind, these units ensure that cooling does not come at the expense of peace and quiet, making them perfect for bedrooms or offices where a tranquil environment is essential.

In addition to performance, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are also equipped with comprehensive filtration systems. These filters capture dust, allergens, and pollutants, promoting better air quality within indoor spaces. This is particularly beneficial for individuals with allergies or respiratory concerns.

Remote control and smart capabilities are also integral features, allowing users to operate and schedule their air conditioner from anywhere within the home. This convenience adds a layer of flexibility to managing indoor climates, especially in today's fast-paced world.

In summary, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU air conditioning units represent a perfect blend of advanced technology, energy efficiency, and user comfort. Their inverter technology, effective air distribution, quiet operation, and enhanced air filtration make them a valuable addition for those seeking reliable climate control while prioritizing sustainability and comfort.