Panasonic CS-KS24NKU, CU-KS24NKU Basic Functions of the Service Valves, Pump Down, Table

Models: CU-KS24NKUA CS-KS24NKU CU-KS24NKU

1 122
Download 122 pages 21.06 Kb
Page 118
Image 118
Basic Functions of the Service Valves

Basic Functions of the Service Valves

The basic functions of the service valves are given in Table 8 below.

Table 8

Action

Narrow Tube Service

Wide Tube Service

Valve (2-Way)

Valve (3-Way)

 

 

CLOSED

O-ring

Valve cap

 

 

 

Stem

Shipping

Fully OPEN

Operating and test running

the air conditioner

 

Fully OPEN

Measuring pressure

*

and gas charging

 

 

CLOSED

Air purging with

*

a vacuum pump

 

Hose with push-pin

CAUTION

Close

*The service port on the wide tube ser- vice valve uses a Schrader core valve to access the refrigerant system.

Therefore, be sure to use a hose con- nector which has a push-pin inside. (Fig. 60a)

Service valve

When opening or closing the service valve stem,

Open

use the hex wrench. Be sure to fully seat the wrench before turning the valve.

Hex wrench

Fig. 60b

PUSH

NOTE

External diameter of service port R410A: 5/16"

Fig. 60a

Pump Down

Pump down means collecting all refrigerant gas in the system back into the outdoor unit without losing any of the gas. Pump down is used when the unit is to be moved or before servicing the refrigerant circuit.

Pump Down Procedure

Be sure to carry out pump down with the unit in cooling mode.

(1)Connect the Lo side charging hose of the manifold valve to the service port on the wide tube service valve.

(2)Using a hex wrench, turn the narrow tube service valve clockwise all the way to close the service valve. (Be sure to confirm that the wide tube service valve is fully open.)

(3)Press the operation button and start cooling oper- ation.

(4)When the low pressure gauge reading falls to 14.2 to 7.1 psi (1 to 0.5 kg/cm2), fully close the wide tube valve stem. Then quickly stop the unit.

(5)Disconnect all gauges and hoses, and replace the valve caps as they were before.