Warning

If refrigerant gas blows off during the work, do not touch the refrigerant gas as it may cause frostbite.

 

 

Prohibit

If refrigerant gas leaks during the work, ventilate the room.

 

If refrigerant gas catches fire, harmful gas may be generated.

 

 

 

Do not mix any gas other than the specified refrigerant gas in the refrigerating cycle.

 

If air or other contaminants mix with the gas, pressure will become extremely high in the refrigerating cycle,

 

which may cause a unit breakdown."

Prohibit

 

 

When the welded section of the compressor intake or discharge pipe is to be disconnected, perform it in

 

a well-ventilated place after sufficiently recovering the refrigerant gas.

 

Any residue gas may jet out refrigerant or refrigerating machine oil, which may cause an injury.

 

 

 

When the work is to be performed in a high place (About 2 meters or more), make sure to wear a safety helmet,

 

gloves and safety belt. Insufficient safety gear may cause a serious injury in case of a fall.

 

 

 

When the unit is to be relocated, confirm that the new installation location has sufficient strength for the weight of the unit.

 

Insufficient strength of the installation location and incomplete installation work may cause an injury due to

 

the unit falling.

 

 

 

When the remote controller batteries are replaced, dispose of the old batteries out of the reach of children.

 

If a child swallows a battery, make sure that the child gets immediate medical attention.

 

 

 

Caution

Do not wash the air conditioner with water, as this may cause an electric shock or fire. Prohibit

For the repair work in places with high humidity or moisture, make sure to ground the unit.

Failure to do so may cause an electric shock.

Confirm that the component attachment position, wiring condition, soldering condition and connector connection are normal.

If not, it may cause overheating or fire.

Confirm that the temperature around the compressor is not too high, and then perform the repair work.

Failure to do so may cause a burn.

Perform welding work in a place with good ventilation.

If the work is performed in a poorly ventilated area, it might cause a lack of oxygen.

If the installation plate or attachment frame has deteriorated due to corrosion, etc., replace it.

Failure to do so may cause an injury due to the unit falling.

When the cleaning is to be performed, make sure to turn off the power and pull out the plug.

Touching the fan that is rotating at high speed may result in an injury.

When the indoor unit is to be removed, do not place it on an incline.

Doing so may cause wet furniture because water left inside may trickle down.

Prohibit

Do not hold the sharp end of the unit or the aluminum fins, as it may cause an injury to your hand or finger. Prohibit

After repairs, make sure to measure the insulation resistance and confirm that the value is 1 Mohm or more.

Any insulation error may cause an electric shock.

After repairs, make sure to check the drainage of the indoor unit.

Inappropriate drainage may cause wet furniture and floors due to water leakage.

3

Page 3
Image 3
Panasonic CS-KS24NKU, CU-KS24NKUA service manual Prohibit

CU-KS24NKUA, CS-KS24NKU, CU-KS24NKU specifications

The Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are a part of the company’s advanced air conditioning lineup, known for their efficient performance and user-friendly features. Designed to provide optimal cooling while ensuring energy efficiency, these models cater to both residential and commercial spaces, making them an ideal choice for various settings.

One of the standout features of the Panasonic CU-KS24NKUA and its counterparts is their inverter technology. This innovative approach allows the air conditioning units to adjust their cooling capacity based on the room's temperature, thus ensuring that they operate at peak efficiency. By minimizing energy consumption during low demand, the units not only lower electricity bills but also reduce environmental impact.

The CU-KS24NKU series is equipped with a powerful compressor that delivers high cooling performance, capable of rapidly cooling spaces even in extreme heat conditions. Additionally, with a robust SEER (Seasonal Energy Efficiency Ratio) rating, these models rank among the top in energy savings, making them suitable for energy-conscious consumers.

Continuous airflow is vital for maintaining a comfortable indoor environment, and the CS-KS24NKU includes features that enhance air circulation. Utilizing a multi-directional airflow system, these units ensure that cool air is distributed evenly throughout the room, minimizing hot spots and maximizing comfort.

Another significant characteristic of the Panasonic air conditioners is their silent operation. Designed with low noise levels in mind, these units ensure that cooling does not come at the expense of peace and quiet, making them perfect for bedrooms or offices where a tranquil environment is essential.

In addition to performance, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are also equipped with comprehensive filtration systems. These filters capture dust, allergens, and pollutants, promoting better air quality within indoor spaces. This is particularly beneficial for individuals with allergies or respiratory concerns.

Remote control and smart capabilities are also integral features, allowing users to operate and schedule their air conditioner from anywhere within the home. This convenience adds a layer of flexibility to managing indoor climates, especially in today's fast-paced world.

In summary, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU air conditioning units represent a perfect blend of advanced technology, energy efficiency, and user comfort. Their inverter technology, effective air distribution, quiet operation, and enhanced air filtration make them a valuable addition for those seeking reliable climate control while prioritizing sustainability and comfort.