9-4-2. Outdoor Fan Motor

This outdoor DC fan motor contains an internal control PCB. Therefore, it is not possible to measure the coil resistance, and the following procedure should be used to check the motor.

Perform the trouble diagnosis by Test Run mode described on Installation Instructions.

Important: (A) Turn OFF the power before connecting or disconnecting the motor connectors.

(B)When performing voltage measurement at the outdoor controller connector for (3) in the table below, the DC motor will trip and voltage output will stop approximately 10 seconds after operation is started. For this reason, to measure the voltage again, first turn OFF the outdoor unit power, then, measure the voltage in Test Run mode.

[Trouble symptom 1] The fan does not stop when the outdoor unit stops. Outdoor unit controller trouble

[Trouble symptom 2] The fan motor does not rotate when the outdoor unit is operating.

(Diagnostic procedure)

*Disconnect the motor connectors and measure the voltage at the DC motor connectors on the outdoor unit controller (3 locations).

Measurement location

Normal value

 

 

(1) Vs-Gnd : Between pin 1 and pin 4

 

or

DC 230V or more

Vm-Gnd : Between pin 1 and pin 4

 

 

 

(2) Vcc-Gnd : Between pin 5 and pin 4

DC 14V or more

 

 

(3) Vsp-Gnd : Between pin 7 and pin 4

After fluctuating 4 times between DC 1.7 to 6.1V

 

(1 sec. ON) and DC 0 V (1 sec. OFF), the DC

 

motor trips.

 

 

(Diagnostic results)

All of the above measured values are normal. Fan motor trouble (Replace the motor.) Any one of the above measured values is not normal. Outdoor unit controller trouble

(Replace the controller .)

(Reference) DC motor connector pin arrangement

CU-KS18NKU / CU-KS18NKUA

Pin 1: Vs (white)

Pin 2: Not used

Pin 3: Not used

Pin 4: Gnd (black)

Pin 5: Vcc (red)

Pin 6: FG (blue)

Pin 7: Vsp (yellow)

CU-KS24NKU / CU-KS24NKUA

Pin 1: Vm (red)

Pin 2: Not used

Pin 3: Not used

Pin 4: Gnd (blue)

Pin 5: Vcc (brown)

Pin 6: PG (white)

Pin 7: Vsp (orange)

[Trouble symptom 3] Motor rotates for some time (several seconds), but then quickly stops, when the outdoor unit operates.

(There is trouble in the system that provides feedback of motor rotation speed from the motor to the outdoor unit controller.)

[Trouble symptom 4] Fan motor rotation speed does not change during outdoor unit operation. [Trouble symptom 5] Fan motor rotation speed varies excessively during outdoor unit operation.

(Remedy for symptom 3 to 5)

It is not possible to identify whether the trouble is outdoor unit controller trouble or motor trouble. Therefore, first replace the outdoor unit controller, then (if necessary) replace the DC motor.

55

Page 55
Image 55
Panasonic CS-KS24NKU service manual Outdoor Fan Motor, CU-KS24NKU / CU-KS24NKUA

CU-KS24NKUA, CS-KS24NKU, CU-KS24NKU specifications

The Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are a part of the company’s advanced air conditioning lineup, known for their efficient performance and user-friendly features. Designed to provide optimal cooling while ensuring energy efficiency, these models cater to both residential and commercial spaces, making them an ideal choice for various settings.

One of the standout features of the Panasonic CU-KS24NKUA and its counterparts is their inverter technology. This innovative approach allows the air conditioning units to adjust their cooling capacity based on the room's temperature, thus ensuring that they operate at peak efficiency. By minimizing energy consumption during low demand, the units not only lower electricity bills but also reduce environmental impact.

The CU-KS24NKU series is equipped with a powerful compressor that delivers high cooling performance, capable of rapidly cooling spaces even in extreme heat conditions. Additionally, with a robust SEER (Seasonal Energy Efficiency Ratio) rating, these models rank among the top in energy savings, making them suitable for energy-conscious consumers.

Continuous airflow is vital for maintaining a comfortable indoor environment, and the CS-KS24NKU includes features that enhance air circulation. Utilizing a multi-directional airflow system, these units ensure that cool air is distributed evenly throughout the room, minimizing hot spots and maximizing comfort.

Another significant characteristic of the Panasonic air conditioners is their silent operation. Designed with low noise levels in mind, these units ensure that cooling does not come at the expense of peace and quiet, making them perfect for bedrooms or offices where a tranquil environment is essential.

In addition to performance, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are also equipped with comprehensive filtration systems. These filters capture dust, allergens, and pollutants, promoting better air quality within indoor spaces. This is particularly beneficial for individuals with allergies or respiratory concerns.

Remote control and smart capabilities are also integral features, allowing users to operate and schedule their air conditioner from anywhere within the home. This convenience adds a layer of flexibility to managing indoor climates, especially in today's fast-paced world.

In summary, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU air conditioning units represent a perfect blend of advanced technology, energy efficiency, and user comfort. Their inverter technology, effective air distribution, quiet operation, and enhanced air filtration make them a valuable addition for those seeking reliable climate control while prioritizing sustainability and comfort.