(3) Serial Communication Error Identification Procedure

If the lamps on the main body show the following conditions after the completion of self-diagnostics, a communication error between the indoor unit and outdoor unit might be considered.

In such a case, identify the breakdown section by using the following procedure.

NOTE Refer to "Method of Self-Diagnostics" for the self-diagnostics procedure.

Lamp

Quiet

Timer

Operation

Condition

(3)

(2)

(1)

E01

 

 

 

E12

 

 

 

< Before the Operation >

: Off

: Blinking

: Illuminated

WARNING

CAUTION

For terminal strip short circuit work or inter-unit wiring removal, turn off the power to avoid an electric shock.

Release the terminal strip short circuit after the completion of self-diagnostics.

Do not perform the short-circuit work between any other terminals except for specified ones on the specified terminal strip. If such work is performed between the incorrect terminals, the unit might be broken.

 

 

 

 

 

 

 

 

< Convenient Tool for Short-Circuit Work ( for example ) >

 

 

 

Cable

Alligator Clip

Alligator Clip

 

< Check Items before Troubleshooting Serial Communication Start >

After confirming that the following errors do not exist, start the "Troubleshooting Serial Communication" in "Condition: E01 and E12".

1.

Mis -wiring (inter-unit cable, etc.)

6.

Reactor failure (defective insulation, etc.)

2.

AC power failure

7.

High-Pressure Switch failure

3.

Blown fuse

8.

Overload Relay failure

4.

Power Relay failure

9.

Magnetic Coil failure (defective insulation, short-circuit, etc.)

5.

Outdoor Fan Motor failure (defective insulation, etc.)

10. Compressor failure (defective insulation, etc.)

 

 

 

 

(3-1) Condition: E01

Troubleshooting Serial Communication

Is the voltage of about DC12V

or more given between the terminals

2 and 3 on the outdoor unit terminal strip

(Serial Communication Line) ?

(Fig. 1)

Yes

A

( Continued to the next page A. )

 

 

 

-

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

1

 

2

 

3

 

4

 

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

 

4

5

6

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

1

 

2

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

 

3

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

Indoor Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2

 

 

 

 

 

1.Turn OFF the power and wait until the power lamp (LED)

No of the outdoor unit controller is turned OFF.

2.Disconnect the cable from the terminal 3 on the indoor unit

terminal strip.

(Fig. 2)

3. Turn ON the power.

 

B

( Continued to the next page B. )

51

Page 51
Image 51
Panasonic CU-KS24NKU Serial Communication Error Identification Procedure, Before the Operation, Off Blinking Illuminated

CU-KS24NKUA, CS-KS24NKU, CU-KS24NKU specifications

The Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are a part of the company’s advanced air conditioning lineup, known for their efficient performance and user-friendly features. Designed to provide optimal cooling while ensuring energy efficiency, these models cater to both residential and commercial spaces, making them an ideal choice for various settings.

One of the standout features of the Panasonic CU-KS24NKUA and its counterparts is their inverter technology. This innovative approach allows the air conditioning units to adjust their cooling capacity based on the room's temperature, thus ensuring that they operate at peak efficiency. By minimizing energy consumption during low demand, the units not only lower electricity bills but also reduce environmental impact.

The CU-KS24NKU series is equipped with a powerful compressor that delivers high cooling performance, capable of rapidly cooling spaces even in extreme heat conditions. Additionally, with a robust SEER (Seasonal Energy Efficiency Ratio) rating, these models rank among the top in energy savings, making them suitable for energy-conscious consumers.

Continuous airflow is vital for maintaining a comfortable indoor environment, and the CS-KS24NKU includes features that enhance air circulation. Utilizing a multi-directional airflow system, these units ensure that cool air is distributed evenly throughout the room, minimizing hot spots and maximizing comfort.

Another significant characteristic of the Panasonic air conditioners is their silent operation. Designed with low noise levels in mind, these units ensure that cooling does not come at the expense of peace and quiet, making them perfect for bedrooms or offices where a tranquil environment is essential.

In addition to performance, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU are also equipped with comprehensive filtration systems. These filters capture dust, allergens, and pollutants, promoting better air quality within indoor spaces. This is particularly beneficial for individuals with allergies or respiratory concerns.

Remote control and smart capabilities are also integral features, allowing users to operate and schedule their air conditioner from anywhere within the home. This convenience adds a layer of flexibility to managing indoor climates, especially in today's fast-paced world.

In summary, the Panasonic CU-KS24NKUA, CU-KS24NKU, and CS-KS24NKU air conditioning units represent a perfect blend of advanced technology, energy efficiency, and user comfort. Their inverter technology, effective air distribution, quiet operation, and enhanced air filtration make them a valuable addition for those seeking reliable climate control while prioritizing sustainability and comfort.