5.3.8 When Performing General-purpose Serial Communication
For GT01, GT11 and GT21
Error code
Error name
Measures
ER00 BCC error
The value of BCC may be incorrect. Check if there is no
calculation mistake.
ER01
Format error
A command format may be incorrect. Check if it is correct.
ER02 NOT supported error
A command used is not supported with the version of the
GT. Upgrade the version of the GT, or use another
command.
ER03 Address error
The address specified does not exist in the GT. Check the
address of the transmitted command.
ER04 Receive buffer overflow
The sent command exceeds the receivable number of
bytes. Check the number of bytes of the sent command.
ER05 Requested overflow
The sent readout command exceeds the number of bytes
that can send back. Check the number of the read words.
ER06 Data error
The communication condition for the GT may be
unmatched with the condition for a destination device.
Check the communication conditions.
ER07 Data write inhibit error
A command for the address that writingn is not available
was sent. Check the address of the sent command.
For GT02, GT02, GT05, GT12, GT32 and GT32-E
Error code
Error name
Measures
**0000 BCC error
The value of BCC may be incorrect. Check if there is no
calculation mistake.
**0001
Format error
A command format may be incorrect. Check if it is correct.
**0002 NOT supported error
A command used is not supported with the version of the
GT. Upgrade the version of the GT, or use another
command.
**0003 Address error
The address specified does not exist in the GT. Check the
address of the transmitted command.
**0004 Receive buffer overflow
The sent command exceeds the receivable number of
bytes. Check the number of bytes of the sent command.
**0005 Requested overflow
The sent readout command exceeds the number of bytes
that can send back. Check the number of the read words.
**0006 Data error
The communication condition for the GT may be
unmatched with the condition for a destination device.
Check the communication conditions.
**0007 Data write inhibit error
A command for the address that writingn is not available
was sent. Check the address of the sent command.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net