KX-TC2000NZB / KX-TC2000N ZW / KX-TC2000NZF

12.2. How to change the channel

12.3. Adjustment

 

Adjustment Items

Test Mode

Adjustment

Procedure

Check or

 

 

 

Point

 

Replace

 

 

 

 

 

Parts

(A)

Battery Low

3ch Talk

-

1. Adjust the power supply voltage to DC3.60V,and confirm so that the

IC1

 

Confirmation

 

 

reading of oscillosope is High.

 

 

 

 

 

2. Adjust that power supply voltage to DC 3.40V, and confirm so that the

 

 

 

 

 

reading of oscilloscope is Low.

 

(B)

TX VCO

3ch Talk

T6

1. Adjust T6 so that the reading of the Digital Voltmeter is 1.5V ± 0.3V.

IC1, X1,

 

Adjustment

 

 

 

T6, DV1

(C)

RX VCO

3ch Talk

-

1. Confirm so that the reading of the Digital Voltmeter is 0.7 ~ 3.0V.

IC1, X1,

 

Confirmation

 

 

 

L6, C24

(D)

TX Frequency

3ch Talk

VC1

Adjust VC1 so that the reading of the frequency counter is 39.8750MHz

IC1,

 

Adjustment

 

 

± 100Hz.

DPX1, T5

(E)

TX Power

3ch Talk

-

Confirm so that the reading of the RF VTVM is more than -3.0dBm

IC1,Q3,Q4,

 

Confirmation

 

 

(50Ω load).

Q5, DPX1

(F)

RX Sensitivity

3ch Talk

T3

1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.

DPX1,

 

Confirmation

 

 

0KHz).

T3,IC1,

 

(2nd IF output)

 

 

2. Confirm that the reading of RF VTVM is the maximum value (more than

CF1, CF2

 

 

 

 

 

 

 

 

 

15mV).

 

(G)

Noise Squelch

3ch Talk

-

1. Measure the SSG output level when the noise squelch changes from

IC1, DPX1

 

Confirmation

 

 

Low to High. (modulation frequency 1KHz, dev.3kHz)

 

 

 

 

 

2. Confirm that the SSG output level is -18 ~ 0dBuVemf.

 

(H)

Speaker

3ch Talk

-

1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.

IC1

 

Output Level

 

 

3KHz).

 

 

Confirmation

 

 

2. Confirm that the reading of AF VTVM is more than 30mV.

 

 

 

 

 

 

 

 

 

 

(distortion: less than 5%) (volume High).

 

(I)

Mic Modulation

3ch Talk

-

1. Apply a MIC signal (1KHz, 5.0mV at 600Ω load).

IC1, DV1

 

Factor

 

 

2. Confirmation so that the reading of FM Deviation Meter is 3.4KHz ±

 

 

Confirmation

 

 

 

 

 

 

0.4KHz.

 

 

 

 

 

 

(J)

Data

3ch Talk

-

Confirm for 5.0 ± 1.0KHz FM Deviation Meter reading.

 

 

Modulation

 

 

 

 

 

Confirmation

 

 

 

 

(K)

Battery low

-

-

1. Apply 3.50V between BATT(+) and BATT(-).

IC1

 

Confirmation

 

 

2. Confirm that there is no flashing of RECHARGE LED.

 

 

 

 

 

 

 

 

 

 

3. Apply 3.40V between BATT(+) and BATT(-).

 

 

 

 

 

4. Confirm that there is flashing of RECHARGE LED.

 

The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.30).

SSG Frequency: 30.175 MHz

29

Page 29
Image 29
Panasonic KX-TC2000NZF, KX-TC2000NZB, KX-TC2000NZW manual How to change the channel Adjustment, IC1