KX-TC2000NZB / KX-TC2000N ZW / KX-TC2000NZF

11.2. How to change the channel

*: Refer to Flow Solder Side View (P.68).

11.3. Adjustment

 

Adjustment Items

Test Mode

Adjustment

*Procedure

Check or

 

 

 

Point

 

Replace

 

 

 

 

 

Parts

(A)

RX VCO

3ch Talk

-

Confirm so that the reading of the Digital Voltmeter is 2.0V ± 1.0V.

IC1, L10,

 

Confirmation

 

 

 

C26, R14

(B)

TX VCO

3ch Talk

T6

Adjust T6 so that the reading of the Digital Voltmeter is 2.0V ± 0.3V.

IC1, DV1,

 

Adjustment

 

 

 

T6

(C)

TX Frequency

3ch Talk

VC1

Adjustment VC1 so that the reading of the frequency counter is

IC, X1, T6,

 

Adjustment

 

 

30.1750MHz ± 100Hz.

DV1, C35,

 

 

 

 

 

C40, VC1

(D)

TX Power

3ch Talk

T5

Adjust T5 so that the reading of the RF VTVM is more than 9dBm.

IC1, Q3,

 

Adjustment

 

 

 

Q4, Q5,

 

 

 

 

 

T5, DPX1

(E)

RX Sensitivity

3ch Talk

T2

1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.

DPX1, T2,

 

Confirmation

 

 

0KHz).

CF1, CF2

 

(2nd IF output)

 

 

2. Confirm that the reading of RF VTVM is the maximum value (more than

 

 

 

 

 

 

 

 

 

 

20mV)

 

(F)

Line Output Level

3ch Talk

-

1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.

IC1, Q11

 

Confirmation

 

 

3KHz).

 

 

 

 

 

2. Confirm that the reading of AF VTVM is more than 120mV (600Ω load).

 

(G)

Line Input

3ch Talk

-

1. Input via loop simulator 1.0KHz, -20dBm (measured at T-R) signal.

IC1, DV1

 

Modulation

 

 

2. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev.

 

 

Confirmation

 

 

 

 

 

 

0KHz).

 

 

 

 

 

 

 

 

 

 

3. Confirm so that the reading of FM Deviation Meter is 2.8KHz ± 0.3KHz.

 

(H)

Noise Squelch

3ch Talk

-

1. Measure the SSG output level when the noise squelch changes from Low

IC1, DPX1

 

Confirmation

 

 

to High.

 

 

 

 

 

2. Confirm that the SSG output level is -10 ~ +5dBuVemf.

 

*: The connection of adjustment equipment are as shown in Adjustment Standard (Base Unit) (P.27). SSG Frequency: 39.875 MHz

26

Page 26
Image 26
Panasonic KX-TC2000NZF, KX-TC2000NZB, KX-TC2000NZW manual How to change the channel, Adjustment