KX-TC2000NZB / KX-TC2000N ZW / KX-TC2000NZF
11.2. How to change the channel
*: Refer to Flow Solder Side View (P.68).
11.3. Adjustment
| Adjustment Items | Test Mode | Adjustment | *Procedure | Check or |
|
|
| Point |
| Replace |
|
|
|
|
| Parts |
(A) | RX VCO | 3ch Talk | - | ∙ Confirm so that the reading of the Digital Voltmeter is 2.0V ± 1.0V. | IC1, L10, |
| Confirmation |
|
|
| C26, R14 |
(B) | TX VCO | 3ch Talk | T6 | ∙ Adjust T6 so that the reading of the Digital Voltmeter is 2.0V ± 0.3V. | IC1, DV1, |
| Adjustment |
|
|
| T6 |
(C) | TX Frequency | 3ch Talk | VC1 | ∙ Adjustment VC1 so that the reading of the frequency counter is | IC, X1, T6, |
| Adjustment |
|
| 30.1750MHz ± 100Hz. | DV1, C35, |
|
|
|
|
| C40, VC1 |
(D) | TX Power | 3ch Talk | T5 | ∙ Adjust T5 so that the reading of the RF VTVM is more than 9dBm. | IC1, Q3, |
| Adjustment |
|
|
| Q4, Q5, |
|
|
|
|
| T5, DPX1 |
(E) | RX Sensitivity | 3ch Talk | T2 | 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev. | DPX1, T2, |
| Confirmation |
|
| 0KHz). | CF1, CF2 |
| (2nd IF output) |
|
| 2. Confirm that the reading of RF VTVM is the maximum value (more than |
|
|
|
|
|
| |
|
|
|
| 20mV) |
|
(F) | Line Output Level | 3ch Talk | - | 1. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev. | IC1, Q11 |
| Confirmation |
|
| 3KHz). |
|
|
|
|
| 2. Confirm that the reading of AF VTVM is more than 120mV (600Ω load). |
|
(G) | Line Input | 3ch Talk | - | 1. Input via loop simulator 1.0KHz, | IC1, DV1 |
| Modulation |
|
| 2. Apply 60dBuVemf output from S.S.G. (modulation frequency 1KHz, dev. |
|
| Confirmation |
|
|
| |
|
|
| 0KHz). |
| |
|
|
|
|
| |
|
|
|
| 3. Confirm so that the reading of FM Deviation Meter is 2.8KHz ± 0.3KHz. |
|
(H) | Noise Squelch | 3ch Talk | - | 1. Measure the SSG output level when the noise squelch changes from Low | IC1, DPX1 |
| Confirmation |
|
| to High. |
|
|
|
|
| 2. Confirm that the SSG output level is |
|
*: The connection of adjustment equipment are as shown in Adjustment Standard (Base Unit) (P.27). SSG Frequency: 39.875 MHz
26