LC2H
PRECAUTIONS IN USING THE LC2H SERIES
Cautions for use
1. Insulation sheet
Before using a panel mounting type, please pull and remove the insulation sheet from the side of the product in the direction of the arrow.
In consideration that the product might be stored for long periods without being used, an insulation sheet is inserted before shipping. Remove the insulation sheet and press the front reset button.
•LC2H total counter (one-touch installation type)
Insulation sheet | Reset button |
|
•LC2H total counter (installation frame type)
Insulation sheet | Reset button |
|
2. Waterproof construction
• LC2H total counter (installation frame type)
The operation part of the panel installation type (installation frame type) is constructed to prevent water from entering the unit and a rubber gasket is provided to prevent water from entering the gap between the unit and the panel cutout.
There must be sufficient pressure applied to the rubber gasket to prevent water from entering.
Be sure to use the mounting reinforcement screws when installing the mounting frame (ATH3803).
Note: The
Mounting frame (ATH3803)
• LC2H preset counter
1)The front plate will not be waterproof when this product is installed on a panel. To make the front plate waterproof, please install the following.
When using the waterproof type (IP66: panel front only), install the counter to the front plate with mounting frame ATH3803 (sold separately) and rubber gasket ATH3804 (sold separately). Be sure to tighten using mounting screws.
Mounting frame (ATH3803)
Rubber gasket (ATH3804)
When installing the mounting frame and rubber gasket please remove the
2)Panel installation order
(1)Remove
(2)Place rubber gasket.
(3)Insert counter into panel.
(4)Insert mounting frame from the rear.
(5)Secure with mounting screws (two
locations)
3.Do not use in the following environments
1) In places where the temperature changes drastically.
2) In places where humidity is high and there is the possibility of dew.
(When dew forms the display may vanish and other display errors may occur.)
4.Conditions of use
1)Do not use on places where there is flammable or corrosive gas, lots of dust, presence of oil, or where the unit might be subject to strong vibrations or shocks.
2)Since the cover is made of polycarbonate resin, do not use in places where the unit might come into contact with or be exposed to environments that contain organic solvents such as methyl alcohol, benzene and thinner, or strong alkali substances such as ammonia and caustic soda.
5.Cautions regarding battery replacement
1) Remove wiring before replacing the battery. You may be electrocuted if you come into contact to a part where high voltage is applied.
2) Make sure you are not carrying a static electric charge when replacing the battery.
3) Battery replacement procedure For LC2H total counter
(1)Remove the up/down hook of the case using a tool.
(2)Pull the unit away from the case.
(3)Remove the battery from the side of the unit. Do not touch the display or other parts.
(4)Before inserting wipe clean the surface of the new battery.
(5)Insert the new battery with the “+” and
(6)After replacing the battery, return the unit to the case. Verify that the hook of the case has properly engaged.
(7)Before using, press the reset button on the front.