LC2H |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2. Backlight type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Voltage input type |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Contact input |
|
|
|
| Transistor input |
|
|
|
|
|
|
|
| Backlight connection |
| |||||||
| NPN transistor |
| PNP transistor |
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| +V |
|
| +V | +V |
|
|
|
|
| +V |
| Green |
|
|
| Red |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Count |
|
|
| Reset |
|
|
|
|
|
|
|
|
|
|
|
| 24V DC |
|
|
|
| |
input |
|
|
| input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 |
|
|
|
| 5 |
|
| Count |
| 5 |
|
| Reset |
|
| 5 |
|
|
| 5 |
|
1 | 2 | 3 | 4 | Count |
|
| Reset | 1 | 2 | 3 | 4 | 1 | 2 | 3 | 4 | 1 | 2 | 3 | 4 | |||
|
| input | input | |||||||||||||||||||
| 6 |
|
| 1 2 | 3 | 4 |
| 6 |
|
| ||||||||||||
|
|
| input | input |
|
|
|
|
|
|
| 6 |
|
|
| 6 |
| |||||
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0V |
|
|
| 0V |
|
|
|
|
|
|
|
|
|
|
|
| 24V DC |
Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.
2.2 and 4. (The input and reset circuits are functionally insulated.)
3.When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage Q 50 V, leakage current < 1 µA)
4.Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input terminal, can cause damage to the internal elements.
Explanation of operation
1.Counting takes place when the count input signal is ON.
2.Counting resumes again when the count value reaches 99999999 (full scale value) and then returns to “0” with a new count input.
3.No measurement takes place when a reset is input.
1) When reset is ON, resetting takes place and the count becomes “0”.
2) Press the front reset button when you want to reset manually (only panel installation type).
Note) Be aware that battery life will decrease if the count input or reset input are left ON.
Count input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Reset input |
|
|
|
|
|
|
|
|
|
|
|
|
| ❇ | ||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Count value |
|
|
|
|
|
|
|
|
|
|
|
| ||||
0 | 1 |
|
|
| 99999999 | 0 |
| 1 |
| 0 | 1 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note) ❇Count becomes “1” when the reset input is turned OFF while the count signal is being input.
104