Panasonic LC2H specifications Specifications, Applicable standard, Max. 1.5 W

Models: LC2H

1 34
Download 34 pages 7.45 Kb
Page 11
Image 11
Max. 1.5 W

LC2H

Specifications

 

Item

Descriptions

 

Rated operating voltage

24 V DC

 

Rated power consumption

Max. 1.5 W

 

Rated control capacity

100 mA 30 V DC

 

Input mode

Addition/Subtraction (selectable by front switch)

 

Max. counting speed

30 Hz/5 kHz (selectable by slide switch on side)

 

Counting input

Min. input signal width: 16.7 ms at 30 Hz/0.1 ms at 5 kHz,

 

ON time : OFF time = 1 : 1

 

 

 

Reset input

Min. input signal width: Min. 30 ms

Rating

 

Non-voltage input using contacts or open-collector connection

Input signal

• Input impedance; when shorted: Max. 1 k, when open: Min. 100 k

 

 

 

• Residual voltage: Max. 2 V

 

 

• Maintain output/hold count • Maintain output/over count

 

Output mode

• One shot/over count • One shot/recount

 

 

(Selectable by front switch)

 

Display method

7-segment LCD

 

(Switch between red and green for backlight, and between lit and flashing for count up.)

 

 

 

Digit

–9999999 to 99999999 (–7 digits to +8 digits)

 

(0 to 99999999 for preset value)

 

 

 

Memory

EEP-ROM (Overwriting times: 105 operations or more)

Contact arrangement

1 Form A (Open collector)

Electrical life (contact)

107 operations (at rated control voltage)

 

Allowable operating voltage range

85 to 110% of rated operating voltage

Electrical

Break down voltage (Initial value)

Between input and output: 1,500 V AC, for 1 min.

 

Insulation resistance (Initial value)

Between input and output: 100 M(at 500 V DC)

 

Functional vibration resistance

10 to 55 Hz (1 cycle/min), Single amplitude: 0.15 mm (10 min. on 3 axes)

Mechanical

Destructive vibration resistance

10 to 55 Hz (1 cycle/min), Single amplitude: 0.375 mm (1 hr. on 3 axes)

Functional shock resistance

Min. 98 m/s2 (4 times on 3 axes)

 

 

Destructive shock resistance

Min. 294 m/s2 (5 times on 3 axes)

Operating

Operation temperature

–10 to 55°C +14 to +131°F (without frost or dew)

Storage temperature

–25 to +65°C –13 to +149°F (without frost or dew)

conditions

Ambient humidity

30 to 85% RH (at 25°C 77°F, non-condensing)

 

Protective construction

IP66 (front panel with mounting bracket and rubber gasket)

* The factory default preset value is set to 1000000.

 

Applicable standard

 

(EMI)EN61000-6-4

 

 

 

Radiation interference electric field strength

EN55011 Group1 ClassA

 

Noise terminal voltage

EN55011 Group1 ClassA

 

(EMS)EN61000-6-2

 

 

 

Static discharge immunity

EN61000-4-2

4 kV contact

EMC

 

 

8 kV air

RF electromagnetic field immunity

EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz)

 

 

 

 

10 V/m pulse modulation (895 MHz to 905 MHz)

 

EFT/B immunity

EN61000-4-4

2 kV (power supply line)

 

 

 

1 kV (signal line)

 

Conductivity noise immunity

EN61000-4-6

10 V/m AM modulation (0.15 MHz to 80 MHz)

 

Power frequency magnetic field immunity

EN61000-4-8

30 A/m (50 Hz)

 

 

 

 