Panasonic NE-1456, NE-1856, NE-1846 D. Programming Double Or Treble Quantity Pad, E. Program Lock

Models: NE-1456 NE-2156 NE-2146 NE-1846 NE-1856

1 24
Download 24 pages 45.15 Kb
Page 14
Image 14
D. PROGRAMMING DOUBLE OR TREBLE QUANTITY PAD

How to Operate NE - 2156/NE - 1856/NE - 1456

D. PROGRAMMING DOUBLE OR TREBLE QUANTITY PAD

THE OVEN CAN NOT BE PROGRAMMED WHEN PROGRAM LOCK IS ACTIVATED! (see below)

DO NOT OPEN THE DOOR WHILE PROGRAMMING!

Example: To program 1.5 times of heating time for double quantity into Number/Memory pad “5”

 

PAD

INSTRUCTION

DIGITAL DISPLAY WINDOW

 

 

 

 

1

 

Keep the door closed.

 

Digital Display Window must be blank.

2

Press Prog pad.

PROG

“PROG” will start to blink.

3

5

Press Number/Memory pad “5”.

PROG

 

The selected pad number will appear and currently programmed

1

 

 

information will be indicated.

 

 

 

4

x 2

Press Double Quantity pad.

PROG

 

 

The currently programmed magnification number will appear.

 

 

 

Note: 1.6 times is preset at factory.

 

5

5

Press Number/Memory pads “1” and “5”.

PROG

1

The programmed magnification number will appear.

 

6

 

Press Prog pad.

PROG

“PROG” will stop blinking.

This means that you have completed programming.

• Three seconds later, Digital Display Window will go blank.

Note:

If you want to program your desired magnification number for treble quantity, repeat as above, using Treble Quantity pad instead of Double Quantity pad.

E. PROGRAM LOCK

To Activate Program Lock:

1

2

PAD

INSTRUCTION

DIGITAL DISPLAY WINDOW

 

 

 

Keep the door closed.

Digital Display Window must be blank.

 

Press Prog pad until “PROG”, “P” and “L” appear. (more than five

PROG

 

seconds)

 

“PROG”, “P” and “L” will appear.

In Program Lock mode:

The oven is started by pressing the desired Number/Memory pad. There is no need to press Start pad.

Opening the door cancels the remaining time on the program.

The oven can not be programmed or run manually until the program lock is released.

- 13 -

Page 14
Image 14
Panasonic NE-1456, NE-1856, NE-1846 D. Programming Double Or Treble Quantity Pad, E. Program Lock, To Activate Program Lock