PICTURE Menu

Settings

DYNAMIC IRIS

You can switch automatic adjustment of the lamp and the lens iris on/off.

ON: Automatic adjustment

OFF: No adjustment

WAVEFORM MONITOR

You can monitor whether or not the luminance level of the input signal is in the recommended range by displaying it in the waveform monitor. If the waveform is not in the range, adjust it for the best quality. See “Adjusting the waveform of the input signal” on page 24.

OFF

 

FULL SCAN(Y)

 

FULL SCAN(R)

 

FULL SCAN(G)

 

FULL SCAN(B)

 

SINGLE LINE SCAN(Y)

 

SINGLE LINE SCAN(R)

 

SINGLE LINE SCAN(G)

 

SINGLE LINE SCAN(B)

 

MONITOR POSITION

UPPER LEFT

1.Press F G to move to the required waveform style.

2.Press ENTER to select.

The WAVEFORM MONITOR will be displayed.

3.Adjust the WAVEFORM MONITOR.

See “Adjusting the waveform of the input signal” on page 24.

ADVANCED MENU

From the ADVANCED MENU, you can perform more detailed image adjustment manually.

GAMMA

You can adjust linear intensity at 3 levels. Press I H to increase/decrease 1 point.

Levels

Default setting

 

 

GAMMA HIGH

0

 

 

GAMMA MID

0

 

 

GAMMA LOW

0

 

 

Setting range: -8 to +8

CONTRAST

You can adjust the amount of contrast in RGB colors individually. Press I H to increase/decrease 1 point.

RGB

Default setting

 

 

CONTRAST R

0

 

 

CONTRAST G

0

 

 

CONTRAST B

0

 

 

Setting range: -32 to +32

BRIGHTNESS

You can adjust the brightness in RGB colors individually. Press I H to increase/decrease 1 point.

RGB

Default setting

 

 

BRIGHTNESS R

0

 

 

BRIGHTNESS G

0

 

 

BRIGHTNESS B

0

 

 

Setting range: -16 to +16

COLOR MANAGEMENT

You can manage your own defined color settings. See “Setting your own color profile” on page 26.

NR (Noise Reduction)

You can switch the automatic noise reduction system on/off. Press I H to select the required setting.

ON: Automatic noise reduction

OFF: No noise reduction

NOTE:

Applying noise reduction may affect image quality.

32 - ENGLISH