Monitor Lamp indicators

Managing the indicated problems

Indicators Power indicator

Lamp1 (LAMP1) indicator Lamp2 (LAMP2) indicator Temperature (TEMP) indicator Filter (FILTER) indicator

STANDBY(RED)/

 

LAMP

 

TEMP

FILTER

ON(GREEN)

STANDBY(RED)/

LAMP

TEMP

FILTER

ON(GREEN)

 

 

 

If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow.

1.Confirm the status of all indicators and projector, and switch off the projector in proper way.

2.Find out the cause of the problem by status of each indicator.

3.Follow the instruction for each indication below and solve the problem.

4.Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.

NOTE:

If no problem is found or the problem remains, do not turn on the projector. Instead contact your nearest dealer.

LAMP1/LAMP2 indicator

Lamp

Information

 

Check point

 

Remedial measure

indication

 

 

 

 

 

 

 

 

 

Did you notice a “REPLACE

This lamp monitor lights up when the lamp

Lighting in red

Indicates the time for

 

LAMP” message on the screen

 

unit used hours have reached 1 800* hours.

replacing the lamp unit

 

when turning on the projector

 

Request the dealer to replace the lamp unit.

 

 

 

 

 

 

power supply?

* 2 800 hours for PT-D5000E only.

Blinking in red

 

Check the lamp unit

Install the lamp unit.

Lamp unit is not installed.

 

compartment.

When lamp unit is installed and still having

once

 

 

 

 

 

the indicator lights, contact to the dealer.

 

 

 

 

 

 

 

Did you turn the power back on

• Wait until the lamp has cooled off, and then

Blinking in red

Error is detected in the

 

immediately after turning it off?

 

turn on the power.

Some error has arisen in the

• Turn off the POWER switch of the projector

3 times

lamp circuit.

 

lamp circuit.

 

properly and contact your nearest dealer.

 

 

• Check for fluctuation (or drop) in

 

 

 

 

 

the source voltage.

 

 

TEMP indicator

Maintenance

Lamp

High temperature inside.

• Check the ventilation port is

Remove the object that is blocking the

 

indication

Information

 

Check point

 

Remedial measure

 

 

 

 

 

 

 

 

 

• Did you turn on the power when

Wait about 5 minutes in the current status.

 

 

Warm-up status

 

the ambient temperature was

Install the unit in a location having an

 

Lighting in red

 

lower than approx. 0 °C (32 °F)?

 

ambient temperature from 0 °C (32 °F) -

 

 

 

 

 

 

 

 

 

45 °C (113 °F).

 

 

 

 

 

 

 

 

(WARNING)

 

blocked.

 

ventilation port.

 

 

 

Is the room air temperature too

Move the projector to a temperature of 0 °C

 

Blinking in red

The filter is excessively

 

dirty and the ventilation is

 

high?

 

(32 °F) - 45 °C (113 °F) and the humidity of

 

once

 

 

 

poor.

Was the temperature warning

 

20 % to 80 % (no condensation).

 

 

 

 

 

 

 

indication displayed?

• Turn off the POWER switch of the projector

 

Blinking in red

High temperature inside.

 

 

twice

(Standby condition)

 

 

 

in proper way and contact the dealer.

 

Blinking in red

Cooling fan has been

 

 

• Turn off the POWER switch of the projector

 

3 times

stopped.

 

 

 

in proper way and contact the dealer.

ENGLISH - 28