'Install the lamp unit cover, and then use a Phillips screwdriver to securely tighten the lamp unit cover fixing screws.

NOTE:

BBe sure to install the lamp unit and the lamp unit cover securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on.

(Connect the mains lead.

)Press the POWER button so that a picture is projected onto the screen.

NOTE:

BIf the mains lead was disconnected during projection when the projector was used the last time, projection will start after the mains lead is connected (when “POWER MEMORY” in the “OPTION2” menu is set to “ON”). Refer to page 44 for details.

*Press the MENU button to display the “MAIN MENU”, and then press the F or G button to select “OPTION2”.

MENU

KEYSTONE

PICTURE

POSITION

INDEX WINDOW

SHUTTER

VOLUME

LANGUAGE

OPTION1

OPTION2

SECURITY

SELECTENTEREXIT

+Press the ENTER button to display the “OPTION2” menu, and then press the F or G button to select “LAMP RUNTIME”.

OPTION2

BACK COLOR BLUE

FRONT/REAR FRONT

DESK/CEILING DESK FAN CONTROL STANDARD

LAMP

POWER

HIGH

 

 

 

LAMP

RUNTIME

1820H

 

 

 

FUNC

1

INDEX

 

 

CONTROL KEY

ON

 

AUTO POW.OFF DISABLE

 

 

 

 

 

 

POWER

MEMORY

ON

SELECT

RETRN

,Press and hold the ENTER button for approximately 3 seconds.

OPTION2

BACK COLOR BLUE FRONT/REAR FRONT DESK/CEILING DESK FAN CONTROL STANDARD

LAMP

POWER

HIGH

TIME

RESET

[POWER OFF]

FUNC

1

INDEX

CONTROL KEY

ON

AUTO POW.OFF DISABLE

POWER MEMORY

ON

SELECT

RETRN

The “LAMP RUNTIME” will change to “TIME RESET [POWER OFF]”.

NOTE:

BIf the MENU button is pressed, the lamp time resetting screen will be cancelled.

-Turn off the power.

This will reset the cumulative usage time for the lamp unit to “0”.

Refer to page 24 for details on how to turn off the power.

52-ENGLISH