When the TEMP indicator and the LAMP indicator are illuminated

There are two indicators on the control panel of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.

LAMP indicator

TEMP indicator

TEMP indicator

Indicator

Illuminated (red)

Flashing (red)

display

(Lamp unit on)

(Lamp unit off)

 

 

 

 

The surrounding temperature or

The surrounding temperature or

 

the temperature inside the

the temperature inside the

Problem

projector has become unusually

projector has become

high.

dangerously high, causing the

 

 

lamp unit to automatically shut

 

 

off.

 

 

 

Possible

BThe ventilation holes may be covered.

cause

BThe ambient temperature in the place of use may be too high.

 

BThe air filter may be blocked.

 

 

 

 

 

BUncover the ventilation holes.

 

 

BSet up the projector in a place where the temperature is

 

between 0 °C (32 °F) and 40 °C (104 °F) and the humidity is

 

between 20% and 80% (with no condensation). [If you set the

Remedy

“HIGHLAND” to “ON” (page 50), set up the projector in a place

where the temperature is between 0 °C (32 °F) and 35 °C

 

 

(95 °F) and the humidity is between 20% and 80% (with no

 

condensation).]

 

 

BDisconnect the power cord by following the procedure on page

 

28, and then clean the air filter. (Refer to page 56.)

 

 

 

 

LAMP indicator

 

 

 

 

 

Indicator

Illuminated (red)

Flashing (red)

display

 

 

 

 

 

 

 

 

It is nearly time to

An abnormality has been detected in the lamp

Problem

replace the lamp

circuit.

 

 

unit.

 

 

 

 

 

 

 

BDoes “REPLACE

BThe power may

BThere may be an

Possible

LAMP” appear on

have been turned

abnormality in the

the screen after

on straight away

lamp circuit.

cause

the projector is

after it was turned

BThe lamp unit may

 

 

turned on?

off.

be blown.

 

 

 

 

 

BThis occurs when

BWait for a while

BDisconnect the

 

the operation time

until the lamp unit

power cord by

 

for the lamp unit is

cools down before

following the

 

nearing 2 250

turning the power

procedure on

 

hours. Ask your

back on again.

page 28, and then

 

dealer or an

 

contact an

Remedy

Authorized

 

Authorized

 

Service Center to

 

Service Center.

 

replace the lamp

 

BAsk your dealer or

 

unit. (page 57)

 

an Authorized

 

 

 

Service Center to

 

 

 

replace the lamp

 

 

 

unit. (page 57)

 

 

 

 

NOTE:

BBe sure to disconnect the power cord by following the procedure given in “Turning off the power” on page 28 before carrying out any of the procedures in the “Remedy” column.

BIf the TEMP indicator is illuminated and the power turns off after the procedures in the “Remedy” column have been carried out, it means an abnormality has occurred. Please contact an Authorized Service Center so that the necessary repairs can be made.