Displaying System Information
7-22 9161-A2-GH30-30
April 1998

Table 7-2. Health and Status Messages (5 of 5)

Message What To DoWhat It Indicates
Device Fail
yyyyyyyy
The operating software
detects an internal error.
(yyyyyyyy
represents an
eight-digit hexadecimal failure
code for use by service
personnel) This condition
clears after a reset of the unit.
Contact your service
representative.
Module MisConfig,
Slot
ss
The APM in slot
xx
is not the
one specified in the NAM’s
configuration table.1, 2
1. Replace the APM with the
type of APM specified by
the configuration table.
2. Change the current
configuration to reflect the
type of APM in the slot. To
do this, edit the
configuration, accept the
APM, then save the
configuration.
Module Unsupported,
Slot
ss
The NAM does not recognize
the APM.1, 2
A Dual DSX APM has been
installed in a Model 916x T1
Access Unit.
1. Check that an E&M Voice
APM, FXS Voice APM,
FXO Voice APM, Dual DSX
APM, or Sync Data APM is
installed in Slot
ss
.1
2. For Model 926x T1 Access
Mux, check that there is not
more than one DSX APM
installed (only one is
supported).
3. Re-download the NAM
software if new APMs are
supported in later releases.
4. Replace the APM.
5. Contact your service
representative.
Remove the Dual DSX APM.
1
ss
represents physical slots.
2 Does not apply to the access carrier.
Self-Test Results Messages

All self-test results messages appear in the middle column of the System and

Test Status screen (see Table 7-3).