Displaying System Information
7-24 9161-A2-GH30-30
April 1998
Test Status Messages

The right-most column of the System and Test Status screen display the tests

that are currently active on the card (NAM or APM) (see Table 7-4).

Table 7-4. Test Status Messages (1 of 2)

Message What It Indicates

No Test Active No tests are currently running.
Network
n
LLB Test Active A network Line Loopback (LLB) test is active on specified
Network interface (
n
).
DSX
ss-p
LLB Test Active A DSX-1 Line Loopback (LLB) test is active on slot
ss
,
port
p
.
Network
n
PLB Test Active A network Payload Loopback (PLB) test is active on
specified Network interface (
n
).
DSX
ss-p
PLB Test Active A DSX-1 Payload Loopback (PLB) test is active on slot
ss
,
port
p
.
Network
n
RLB Test Active A network Repeater Loopback (RLB) test is active on
specified network interface (
n
).
DSX
ss-p
RLB Test Active A DSX-1 Repeater Loopback (RLB) test is active on slot
ss
, port
p
.
DCLB, Slot
ss
Port
p
A Data Channel Loopback (DCLB) test is active on slot
ss
,
port
p
.
DTLB, Slot
ss
Port
p
A Data Terminal Loopback (DTLB) test is active on slot
ss
,
port
p
.
DTPLB, Slot
ss
Port
p
A Data Terminal Payload Loopback (DTPLB) test is active
on slot
ss
, port
p.
Latching OCU LB, Slot
ss
Port
p
A Latching OCU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
Non-Latching OCU LB,
Slot
ss
Port
p
A Nonlatching OCU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
Latching CSU LB, Slot
ss
Port
p
A Latching CSU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
Non-Latching CSU LB,
Slot
ss
Port
p
A Nonlatching CSU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
Latching DSU LB, Slot
ss
Port
p
A Latching DSU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
Non-Latching DSU LB,
Slot
ss
Port
p
A Nonlatching DSU Loopback test is on the OCU-DP
interface in slot
ss
, port
p
.
OCU Line LB, Slot
ss
Port
p
An OCU Line Loopback test is on the OCU-DP interface in
slot
ss
, port
p
.
OCU Data LB, Slot
ss
Port
p
An OCU Data Loopback test is on the OCU-DP interface
in slot
ss
, port
p
.