Paradyne 9128-II, SLV 9128 technical manual Checking PVC Connections

Models: 9128-II SLV 9128

1 32
Download 32 pages 12.58 Kb
Page 25
Image 25

Checking PVC Connections

Check PVC connections to verify that all PVCs, including management PVCs, are configured, and to see whether the PVC is active or not.

Procedure

1.Press Esc to return to the Status menu.

2.Select PVC Connection Status.

The PVC Connection Status screen shows all PVC connections; the interface and DLCI number of the source interface and DLCI number for the destination interface. You can also see whether the PVC is active.

3.Verify that each PVC is active.

If active, the FrameSaver unit should be passing data.

If not active, no data traffic can be carried by the PVC. If the PVC is configured correctly, the circuit may be down.

25

Page 25
Image 25
Paradyne 9128-II, SLV 9128 technical manual Checking PVC Connections