Command Line Interface for 4000E and 12000E BACs, Micro DSLAMs, and Network Extenders User's Guide (Document Number CLI-A2-GB20) or the Network Management System User's Guide (Document Number NMS-A2-GB20) for further information.

LED Indicators

For purposes of the following descriptions, a pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.

Table 9. LEDs (1 of 3)

 

State

Indication

Additional Information

 

 

 

 

PWR

Solid green

SMD2000-24T is receiving

Both power terminals are

(power)

 

power

connected.

 

 

 

 

 

Solid

SMD2000-24T is receiving

One of the two power

 

amber

power

terminals is connected.

 

 

 

 

 

No

No power

If the SMD2000-24T is not

 

illumination

 

receiving power, none of the

 

 

 

LEDs will be illuminated.

 

 

 

 

FAN

Solid green

All four fans are fully

 

 

 

functional

 

 

 

 

 

 

Solid

Fan failure

At least one of the four

 

amber

 

chassis fans is not

 

 

 

functioning properly.

 

 

 

 

 

No

Total fan failure

None of the four chassis

 

illumination

 

fans is functioning properly.

 

 

 

 

20

Page 20
Image 20
Paradyne SMD2000-24T installation instructions LED Indicators, LEDs 1 State Indication Additional Information